Display during Operation
Operating mode
mA
mA
Lev
Alarms and statuses
Lev = Level alarm
Flw = Flow alarm
Paragraph 3 - Dosage Proportional to Signal 20-4/0 mA
Programming
PROG
Configuration
Pump Funtions
-
+
Pump
Functions
20-4/0 mA
20-4/0 mA
Low
20.0mA
-
20-4/0 mA
High
4.0mA
-
Display during Operation
Operating mode
mA
mA
Lev
Alarms and statuses
Lev = Level alarm
Flw = Flow alarm
Paragraph 4 – Proportional to External Impulses (multiplication)
Programming
PROG
Configuration
Pump Funtions
-
+
Pump
Functions
Multiply (1:n)
Multiply (1:n)
n
4
-
Multiply (1:n)
Timeout
0s
-
Multiply (1:n)
Memory
Off
-
EM00136078
FLOW sensor
Programmed value
status
Programmed interval value
(default: 4-20)
F F
F
4-20
Stop
P100%
(depends on the selected unit
Pump status
Empty = pump in start
Stop = pump stationary
Paus = pump in pause
This function has to be enabled via the "advanced" menu. Please refer to
the programming menu for details.
The pump proportionally doses at a signal of 20-4(0) mA. On the basis of
the factory settings, the pump interrupts dosage at 20mA and doses at the
maximum set frequency when it receives 4 mA. These two values can be
modified during programming. The maximum frequency can be modified
-
+
during operation, by pressing the
-
+
increase the flow, or the
FLOW sensor
Programmed value
status
Programmed interval value
(default: 20-4)
F
F F
20-4
Stop
P100%
(depends on the selected unit
Pump status
Empty = pump in start
Stop = pump stationary
Paus = pump in pause
The pump doses in proportion to an external signal
counter). With every signal received, the pump makes the programmed
"n" number of strikes. The pump automatically sets the dosage frequency,
adapting it to the time that passes between two successive signals. It is
possible to set the time (timeout) in seconds, beyond which the pump
resets the interval count in order to avoid dosages over excessively long
times. The pump has a memory function, which signals the reception of a
signal during dosage. If set to Off, it merely sends a signal, if set to On it
sends a signal and memorises the impulses, then executes them when it
-
+
has finished receiving signals.
-
The value of "n" can be modified during operation, by pressing the
+
-
keys at the same time to increase the flow, or the
+
decrease it.
Current dosage value
of measurement)
Percentage, Frequency,
l/h, Gph, ml/m
Current dosage value
of measurement)
Percentage, Frequency,
l/h, Gph, ml/m
rev. 2.6
Display during Setting (MODE key)
Operating mode
Displays the Low and High
value in sequence
Low
0.0 mA
Current dosage value
Makes it possible to modify the
maximum dosage value by pressing
the + or – buttons at the same time
Operation
keys at the same time to
keys to decrease it.
Display during Setting (MODE key)
Operating mode
Displays the Low and High
value in sequence
High
0.0 mA
Current dosage value
Makes it possible to modify the
maximum dosage value by pressing
the + or – buttons at the same time
Operation
(i.e.: impulse launch
Input mA
value
0
P100%
Input mA
value
0
P100%
keys to
4