7. Insert into the solvent of the metal container the
product return tubing (probe) (Nº 9 diagram 1). Firmly
fastening it to prevent splashes.
8. Open the air passage tap to the pump (Nº 14 diagram
1).
9. Turn the air inlet regulator control of the equipment (Nº
5 diagram 1) turning it clockwise until the equipment
starts up.
10. Keep the equipment running until it is deemed that it
is free of product.

13.2 AFTER SPRAY GUN APPLICATION

1. Activate the gun's safety latch.
2. Adjust the air pressure inlet regulator of the equipment
(Nº 5 in diagram 1) by turning it clockwise until a pressure
of 2 - 2.5 bar is reached.
3. Adjust the air inlet regulator control to the gun (Nº 6 in
diagram 1) by turning it clockwise and pulling its trigger in
order to expel the air in the hose.
4. Adjust the control of the product pressure regulator (Nº
8 in diagram 1), turning it clockwise until a pressure of 1
bar is reached.
5. Remove the absorption probe (diagram DM01/300 Nº
02 and 06 in diagram DM01/400) of the transferred
product container.
6. Deactivate the gun's safety latch and place it in a
grounded metal container with the appropriate solvent.
Take care when placing the gun, which should also be
grounded, in this container.
7. Pull and keep the gun's trigger pulled until product
stops coming out of it.
8. Without releasing the trigger, close the air passage tap
to the pump (Nº 14 diagram 1).
9. Once again activate the gun's safety latch
10. Adjust the air pressure inlet regulator control of the
pump (Nº 5 in diagram 1) by turning it counter clockwise.
11. Adjust the product pressure outlet regulator control
(Nº 8 in diagram 1) by turning it counter clockwise.
12. Open and keep open the bleeding tap (Nº 15 diagram
1), inserting the product return tubing (probe) (Nº 9
diagram 1) into the container of the product to be applied.
13. Fit the absorption probe (diagram DM01/300 Nº 02
and 06 in diagram DM01/400) into a properly grounded
metal container with the appropriate solvent. Take care
when placing the probe, which should also be grounded,
in this container.
14. Fit the product return tubing of the bleeding mecha-
nism (probe) (Nº 9 diagram 1) into the same metal contai-
ner that contains the solvent and secure it appropriately to
prevent splashes.
15. Open the air passage tap to the pump (Nº 14 diagram
1).
16. Turn the air inlet regulator control of the equipment
(Nº 5 in diagram 1) turning it clockwise until the equip-
ment starts up.
17. Keep the equipment running until it is deemed that it
is free of product.
18. Close the product outlet tap (Nº 15 diagram 1).
Before starting to work, verify the state of the product
hoses and the connections of the elements through which
the product flows.
In order to carry out maintenance or repairs, first discon-
nect the unit from the compressed air distribution
network.
Never move the unit by dragging it by the hoses.
Do not apply excessive force or inadequate tools for
maintaining and cleaning the unit. Some repairs must be
done with special tools on some occasions. In these
cases, you must contact the SAGOLA's Customer Servi-
ce. Any handling of this product by non-authorised
personnel will render the warranty null and void.
19. Place the gun into a grounded metal container with
the appropriate solvent. Take care when placing the gun,
which should also be grounded, in this container.
20. Deactivate the gun's safety latch.
21. Pull and keep the gun's trigger pulled until product
stops coming out of it.
22. Adjust the control of the product pressure regulator
(Nº 8 in diagram 1), turning it clockwise until a pressure of
1 bar is reached.
23. Solvent will start to come out of the gun. Keep the
equipment running until it can be seen that it is free of
product.
24. Close the air passage tap to the equipment (Nº 14 in
diagram 1), not releasing the trigger of the gun until
solvent stops coming out of the gun.
25. Adjust the control of the product pressure regulator
(Nº 8 in diagram 1), turning it counter clockwise until a
pressure of 0 bar is reached.
26. Adjust the air pressure inlet regulator control of the
equipment (Nº 5 in diagram 1) by turning it counter
clockwise.
27. Open the bleed tap (Nº 15 diagram 1)
13.3. ANTIPULSATIONS FILTER (diagram DM01/300
Nº 14 and 04 in diagram DM 01/400)
1. Empty the product from the equipment and perform the
decompression procedure.
2. Unscrew the cover of the antipulsations filter.
3. Extract the product filter (diagram DM01/300 Nº 16 and
Nº 27 in diagram DM01/400) and clean it with the suited
solvent or replace it if necessary.
4. Assemble the product filter.
5. Assemble, by tightening to the utmost, the cover of the

antipulsations filter..

IMPORTANT
The gun can be cleaned with solvents or detergents
in a spray gun washing machine.
If you opt for this cleaning system, we advise you take into
account the following considerations, which, if not
applied, may damage the gun and render the warranty
null and void.
- Do not submerge the gun in solvent or detergent longer
than the time required for cleaning.
- Do not use the gun immediately after cleaning has been
completed.
- Ensure that there is no solvent or detergent inside it and
that it is completely free of these.

14. MAINTENANCE

The unit must be overhauled on a regular basis to check
the status of its components and replace these when they
are not in perfect condition.
For most types of use it is not necessary to grease the
pump, except for the O-rings that must be greased during
repairs.
When it is necessary to lubricate the air, do this with
detergent-free SAE 10 oil and adjust the air lubricator to
no more than one drop a minute.
THE BEST POSSIBLE RESULTS, ALWAYS USE
ORIGINAL SAGOLA SPARE PARTS THAT ENSURE
COMPLETE INTERCHANGEABILITY, SAFETY AND
-25-
IN ORDER TO OBTAIN
PERFECT OPERATION.