Storage; Transport; Care And Maintenance; Safety Inspection/ Maintenance Contract - Kärcher HDS 5/13 U Manual De Instrucciones

Ocultar thumbs Ver también para HDS 5/13 U:
Tabla de contenido
Shutdown
For longer work breaks or if a frost free stor-
age is not possible:
 Drain water.
 Flush device with anti-freeze agent.
Dump water
 Screw off water supply hose and high
pressure hose.
Illustration
 Lay the appliance on its rear.
 Operate the appliance for a max. of 1
minute with cold water until the pump
and conduits are empty.
Flush device with anti-freeze agent
Note: Observe handling instructions of the
anti-freeze agent manufacturer.
 Fill commercial grade anti-freeze into
the water connection.
 Switch on appliance (without heater) till
the appliance has been completely
rinsed.
A certain corrosion protection is achieved
with this as well.
CAUTION
Risk of injury and damage! Note the weight
of the appliance in case of storage.

Transport

DANGER
Risk of injury! Risk of tipping with high in-
clines, if the inclination is too large to the
side and with unstable surfaces.
– The appliance should only be used on
gradients of max. 2%.
– Only use the machine on sound surfac-
es.
CAUTION
Risk of injury and damage! Observe the
weight of the appliance when you transport it.
 Lay the appliance on its rear prior to
transporting it and drain the residual
water.
 Pull the device behind you at the carry-
ing handle for transporting it over longer
distances
10

Storage

 To carry, hold the appliance by the han-
dles and the pushing handle.
 When transporting in vehicles, secure
the appliance according to the guide-
lines from slipping and tipping over.

Care and maintenance

DANGER
Risk of injury by inadvertent startup of ap-
pliance and electrical shock.
First pull out the plug from the mains before
carrying out any tasks on the machine.
 Set the appliance switch to "0/OFF".
 Shut off water supply.
 Turn on pump shortly (appr. 5 seconds)
with device switch.
 Set the appliance switch to "0/OFF".
 Activate hand spray gun until device is
pressure less.
 Pull main plug out of socket with dry
hands only.
 Remove water connection.
 Lock the trigger gun.
 Allow device to cool down.
Safety inspection/ maintenance
You can sign with your dealer a contract for
regular safety inspection or even sign a
maintenance contract. Please take advice
on this matter.
Maintenance intervals
Weekly
 Clean filter in the water connection.
Monthly
 Clean filter at the detergent suck hose.
Every 500 operating hours, at least
annually.
 Have the maintenance of the device
performed by the customer service.
– 7
EN
contract
Tabla de contenido
loading

Este manual también es adecuado para:

Hds 5/13 ux

Tabla de contenido