To unlock the buttons:
1. Push and hold the
request for password is displayed.
2. Enter the digits for the password by pressing the
buttons. Press the
move back.
3. When the correct password is set, wait for 5 seconds to unlock
the system.
4. If the wrong password is entered the display will flash -- for 5
seconds then return to normal.
Once the security has been disabled, a password needs to be
re-created to protect the settings.
Thermostat Specifications
Operating Voltage
Maximum Load Current
Output Type
Batteries
Battery Life
Ambient Operating Temperature
Storage Temperature
Operational Mode Chart:
Demand
First Stage Heat
Second Stage Heat
Third Stage Heat
Emergency Heat
First Stage Cool
Second Stage Cool
* G: G is off for Gas, on for Elec
and
to move to the next digit. Press
Conventional
(Non-HP)
W1 + G*
W1 + W2 + G*
N/A
N/A
Y1 + G
Y1 + Y2 + G
14
buttons for 5 seconds until the
1 Amp Max per Output Terminal
2 AA Alkaline in Series
14 °F (-10 °C) to 122 °F (50 °C)
-4 °F (-20 °C) to 140 °F (60 °C)
Heat Pump
(HP) Elec
Y1 + G + B
Y1 + Y2 + G + B
or
Y1 + W2 + G + B
Y1 + Y2 + E +
G + B
or
Y1 + W2 + E +
G + B
Y1 + G + O
Y1 + Y2 + G + O Y1 + Y2 + G + O
E + G
and
to
18-30V AC
4 Amp Total Load
Latching Relays
2 Years Typical
Heat Pump
(HP) Gas
Y1 + G + B
Y1 + Y2 + G + B
or
Y1 + W2 + G + B
E + B
Y1 + G + O
E