Troubleshooting Chart - Campbell Hausfeld AT0510 Manual De Operación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Operating Instructions

Troubleshooting Chart

Stop using tool immediately if any of the following problems occur. Serious personal injury
could occur. Any repairs or replacements must be done by a Qualifi ed Service Person or
Authorized Service Center.
Symptom
Tool runs slowly or will not
operate.
Moisture blowing out of
tool.
Ratchet mechanism slips or
will not loosen nut.
www.campbellhausfeld.com
Possible Cause(s)
1. Grit or gum in tool.
2. No oil in tool.
3. Low air pressure.
4. Air hose leaks.
5. Pressure drops.
6. Worn rotor blade in motor.
7. Worn ball bearing in motor.
1. Water in tank.
2. Water in the air lines/hoses.
1. Ratchet mechanism is dirty.
Corrective Action
1. Flush the tool with air tool oil, gum
solvent, or an equal mixture of SAE 10
motor oil and kerosene. If air tool oil is not
used, lubricate the tool after cleaning.
2. Lubricate the tool according to the
lubrication instructions in this manual.
3a. Adjust the regulator on the tool to the
maximum setting (If applicable).
3b. Adjust the compressor regulator to tool
maximum while the tool is running free.
4. Tighten and seal hose fittings if leaks are
found.
5a. Be sure the hose is the proper size. Long
hoses or tools using large volumes of air
may require a hose with an I.D. of 1/2 inch
or larger depending on the total length of
the hose.
5b. Do not use a multiple number of hoses
connected together with quick connect
fittings. This causes additional pressure
drops and reduces the tool power. Directly
connect the hoses together.
6. Replace rotor blade.
7. Remove and inspect bearing for rust, dirt
and grit or worn race. Replace or clean and
regrease bearing with bearing grease.
1. Drain tank. Oil tool and run until no water
is evident. Oil tool again and run 1–2
seconds.
2a. Install a water separator/filter (PA2121).
NOTE: Separators only work properly when
the air passing through the separator is
cool. Locate the separator/filter as far as
possible from the compressor.
2b. Install an air dryer.
2c. Anytime water enters the tool, the tool
should be oiled immediately.
1. Clean mechanism with air tool oil.