AUTOMATION ACTUATOR MODULE
MaU500erP
5454475 automation actuator module
MaU500erPX 5454476 automation actuator module with external
all YOKIS receivers are compatible with YOKIS transmitters
(remote controls, wall-mounted remote controls,
flush-mounted transmitters).
Technical Specifications
Mains voltage :
230V +/- 15% - 50Hz
Max. load:
2A - 24Vdc
Module consumption:
< 1VA - < 0.3W
Wiring:
Maximum section of cables to be used for mains
voltage: 2.5 mm²
Action type:
1.C
Pollution degree:
2
Rated surge voltage:
2500V
Resistance of plastic
to incandescent:
from 75°C to 125°C.
Ambient temperature:
from -20°C to +40°C
Relative humidity :
0 - 70%
Dimensions :
58 x 84 x 20 mm
Installing Cautions
– In order to follow the safety rules, the module must be connected to a power line that is upstream protected by a magneto-
thermic switch 10A C curve used as overload protection and circuit breaker device.
– Important: The product does not have consolidated insulation between the "Connect" button, the test button, the LED and
the circuit powered by the network; use appropriate insulating tools to access these buttons.
– The module must be installed only by qualified personnel and into a place the end-user cannot access, inside a casing with
IPx4 waterproof enclosure, according to the installing national rules.
– The module must be fixed with screws in the holes provided for this purpose to prevent any movement of the module inside
the control box of the gate.
WIRING
AUTOMATION
0V
OPEN
CLOSE
STOP
GATE
CLOSED
+24V
GATE NOT CLOSED
0V
LINE
NEUTRAL
10A
DS1054-207B
aerial
PB
OPTIONAL
1
2
D600V
3
D600V
4
5
6
7
8
L
N
radIO raNGe:
POWer range:
• Inside 100 m² apartments with perpendicular
crossing of main wall or ceiling.
• 250 m in open range
(Note: in both cases the range may be reduced
by the presence of metallic elements, crossing
of walls, or partitions).
radIO TraNSMISSION:
The transmitter Led will light up only if the
radio transmission was successful.
Adding an intermediate receiver will solve the pro-
blem of an insufficient range.
Refer to the transmitter instruction booklet for
more information.
MAU500ERP(X)
Open A
Open B
Stop NC*
Stop NO*
Etat +
-
Etat
L
230VAC~
50Hz
N
P7
GB
LED
CONNECT
* Wire the automation STOP
according to the behaviour of the
automation to be controlled:
> On Terminal 5 of MAU500ERP(X)
in case of a NC STOP input (e.g.
FAAC gates).
> On Terminal 6 of MAU500ERP(X)
in case of a NO STOP input.