Possible Troubleshooting - EdilKamin NILO Instalación Uso Y Mantenimiento

Ocultar thumbs Ver también para NILO:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 83

POSSIBLE TROUBLESHOOTING

PROBLEM
synoptic panel is off
remote control (optional) not working
output air is not hot
the flame does not appear (remember
that it should appear 5 minutes after
pressing the 0/1 key)
does not ignite
"Battery check" displayed on the
synoptic panel
the ignition/shutdown phase does not
start at the preset time
TROUBLESHOOTING ADVICE
1) Verific./air flow (intervenes if the flow sensor detects insufficient combustion air flow).
Shuts down due to insufficient circulation in the combustion chamber
Flow may be insufficient if the door is open or does not close properly (e.g. flawed seal), if there is a problem with the
air inlet or smoke extraction, if the combustion chamber is blocked or the flow sensor is dirty (clean with dry air).
Check flow sensor limits (within the parameters indicated for the DEALER). The depression alarm may also be
signalled during ignition.
2) Verific./extract. (intervenes if the revolution sensor of the smoke extractor detects an anomaly)
Shuts down due to an anomaly in the revolution sensor of the smoke expulsion motor
- check smoke extractor functionality (connection of the revolution sensor)
- check smoke channel for dirt
- check electrical system (earth)
3) Stop/Flame (intervenes if the thermocouple detects a smoke temperature that is lower than that which is set, thereby
interpreting it as a failure) shuts down due to a drop in the smoke temperature
The flame may not go on for the following reasons:
- lack of pellets
- too many pellets have suffocated the flame
- the maximum thermostat has intervened (this is rare but occurs in an excessive smoke temperature)
CAUSE
no mains voltage
too far from stove
remote control battery flat
too much soot in exchanger
the feed screw has not been filled
accumulation of unburnt residue in
the combustion chamber
the backup battery inside the
control board is flat
incorrect settings:
current time
program activation
activation of the daily program
(for the DEALER)
51
SOLUTIONS
check that the power cable is
connected; check the fuse (on power
socket, page 34)
move closer to the stove
check the battery and if necessary,
replace it
clean the hearth exchanger using the
specific rods (see page 53)
fill the feed screw
(see paragraph regarding ignition,
page 45)
clean combustion chamber
replace the backup battery
verify in accordance with guidelines
Tabla de contenido
loading

Este manual también es adecuado para:

DanubioRio

Tabla de contenido