ELECTRONIC EQUIPMENT

LEONARDO
®
is a combustion safety and control system which allows optimal performance in all
conditions thanks to two sensors measuring the pressure level in the combustion chamber and smoke
temperature.
he detection of and subsequent optimisation of these two parameters is continuous in order to correct
operation anomalies in real time.
he LEONARDO
®
system offers constant combustion, automatically regulating the draft based on the
characteristics of the chimney ue (bends, length, shape, diameter, etc..) and environmental conditions
(wind, humidity, atmospheric pressure, installations at high altitude, etc.).
he standards for installation must be respected.
LEONARDO
system is also able to recognise the type of pellets and automatically d ust the ow mo-
®
ment by moment to ensure the required level of combustion.

ELECTRONIC CIRCUIT BOARD

ventilation
SERIAL PORT
he Dealer can install an optional on the AU outlet for controlling the process of
switching on and off (e.g. telephone remote, local thermostat), located at the rear oh the
stove. an be connected via special optional trestle (code 640560).
BACKUP BATTERY
A backup battery is found on the control board ( - olt R 20 2 battery). Its malfun-
ction is indicated with the following messages (not considered a defect but due to
normal wear-and-tear): "Battery check".
For more detailed information, please contact the DEALER who has performed the rst
1st ignition.
CHARACTERISTICS
M
N
smoke rpm
F
R
backup
battery
lithium
R20 2
D
A
Smoke e pulsion motor
F
M S REW
G
L
H
ow sensor
sensor air
ambient (optional)
P
B
C
ingnition element
2 0 vac power supply
reading points
combustion chamber
FUSE *
two fuses are inserted in the socket with
switch, located on the back of the stove,
one of which operational * and the other
is held in reserve **.
- 25
-
acuum gauge
Reading
points
* **