Figure 2 CP27xx dimensions
Dimension
CP2711
a
308.4 mm (12.14 in.)
b
211.9 mm (8.34 in.)
c
75 mm (2.95 in.)
d
7 mm (0.28 in.)
e
23 mm (0.91 in.)
f
219.5 mm (8.64 in.)
g
148 mm (5.83 in.)
h
26.5 mm (1.04 in.)
Dimension
CP2711
a1
297.5 mm (11.71 in.)
b1
201 mm (7.91 in.)
c1
2—5 mm (0.08—0.2 in.)
CX5130—Install on the mounting rail
Note: Carefully touch the module to prevent damage.
Normal use of the CX5130 system causes high temperatures. The instrument decreases the
temperature through a passive airflow system. The airflow openings are find at the top and bottom of
the module housing. Make sure to install the module horizontally. Keep a minimum clearance of
30 mm (1.2 in.) at the bottom and top side for a correct airflow. Refer to
6 English
Table 1 CP27xx dimensions
CP2716
395.8 mm (15.58 in.)
263.9 mm (10.39 in.)
75 mm (2.95 in.)
7 mm (0.28 in.)
23 mm (0.91 in.)
219.5 mm (8.64 in.)
148 mm (5.83 in.)
51.4 mm (2.02 in.)
Table 2 CP27xx cut out dimensions
CP2716
384.4 mm (15.14 in.)
252.9 mm (9.96 in.)
2—5 mm (0.08—0.2 in.)
CP2718
462.4 mm (18.2 in.)
302.6 mm (11.91 in.)
72.5 mm (2.85 in.)
7 mm (0.28 in.)
20.5 mm (0.81 in.)
219.5 mm (8.64 in.)
148 mm (5.83 in.)
70.8 mm (2.79 in.)
CP2718
451.4 mm (17.77 in.)
291.6 mm (11.48 in.)
2—5 mm (0.08—0.2 in.)
Figure
3.