Installation
Connection to the tumble dryer
The tumble dryer has three options for venting
air: at the back, on the right side and on the left
side. One hole is open when the tumble dryer is
supplied. The other two have covers. The tumble
dryer comes with a connector (1), a plastic band
(2) and a vent hose (3).
1
2
3
Fit the air evacuation system as follows:
1. Slip the vent hose onto the connector and
secure it using the plastic band.
2. Remove the plastic cover if you want to fit the
vent hose to one of the holes other than the
one already open.
3. Insert the connector with the vent hose into the
opening.
4. Place the cover over the open hole.
Connection to the evacuation duct
The vent hose must take the shortest and
straightest route possible from the tumble dryer
to the exhaust air duct. Trim or cut the vent hose
if it is too long. If necessary, the vent hose can be
extended to a maximum of 8 metres (inner
diameter 102 mm). If a longer hose is needed, a
larger inner diameter is required in order to
maintain the tumble dryer's fan capacity. Any
bends must be as gradual as possible. If 90°
bends are necessary then there must be no more
than four. More bends will reduce the tumble
dryer's fan capacity.
WARNING!
Air from the tumble dryer must not be fed through
ducts used for equipment that burns gas or other
fuels.