Multiple PLP-REM installation

For extended installations (total lamp power > 720VA), multiple PLP-REM's
can be linked together. This way, a perfect synchronisation of all pool lights
is still guaranteed.
The PLP-REM's need to communicate with each other, to ensure all the
lamps are in perfect sync.
Connect the PLP-REM's with each other using the CAN bus:
Connect the CAN terminals of the first PLP-REM with the CAN terminal of
the second PLP-REM*.
If more than 2 PLP-REM's are necessary, simply daisy chain each CAN termi-
nal with the one from the next PLP-REM (see below).
polarity of the terminals! (CAN L & H)
Next, set the DIP switches on the PLP-REM's to the correct MASTER/SLAVE
setting. The first PLP-REM will be the MASTER. All the others will be SLAVE's.
Refer to page 9 for Master/Slave DIP switch info.
In a Master/Slave setup, only the PLP-REM-300 that is set as MASTER
!
will react to transmitter commands. Any additional transmitters will
need to be paired with this MASTER PLP-REM-300
set as MASTER
12VAC
* We recommend using a shielded twisted pair cable (min. 0,5mm² - up to 200m) to connect
multiple PLP-REM's using the CAN bus.
set as SLAVE
CAN BUS
230VAC
C
12VAC
230VAC
C
Respect the
set as SLAVE
12VAC
230VAC
C