ARLY-1 Cfg>serial-parameters data-bits 7
ARLY-1 Cfg>serial-parameters parity even
ARLY-1 Cfg>serial-parameters stop-bits 2
ARLY-1 Cfg>
Finalmente es preciso configurar en el Visor Alarm el intervalo de supervisión:
ARLY-1 Cfg>supervision rate 60
ARLY-1 Cfg>
Hasta el momento todo lo configurado se puede consultar mediante el comando SHOW CONFIG
ARLY-1 Cfg>exit
Config>show config
; Showing System Configuration ...
; ATLAS IP Alarm Receiver 2 8 Version 10.2.0
log-command-errors
no configuration
set data-link arly serial0/0
set data-link x25 serial0/1
set data-link x25 serial0/2
network serial0/0
; -- ARLY Interface Configuration --
alarm-receiver receiver-id 6
alarm-receiver line-id 10
alarm-receiver link-test-timer 120
;
supervision port 20300
supervision rate 60
;
;
serial-parameters data-bits 7
serial-parameters parity even
serial-parameters speed 19200
serial-parameters stop-bits 2
exit
;
;
protocol ip
; -- Internet protocol user configuration --
address ethernet0/0 172.28.1.30 255.255.0.0
address ethernet0/0 215.99.32.3 255.255.255.0
;
;
route 0.0.0.0 0.0.0.0 172.28.1.1 1
;
exit
;
dump-command-errors
end
; --- end ---
Config>
Si algún parámetro no se muestra es porque coincide con un valor por defecto de configuración. Para
que la configuración tenga vigencia es preciso guardarla y reiniciar el equipo.
Config>save
Save configuration (Yes/No) [No]? y
Performing memory requirements calculations, please wait
Building system configuration, please wait
Configuration built, saving ...
OK on Flash
Config>
*restart
Are you sure to restart the system(Yes/No)? y
VISOR ALARM – Configuración
III - 29
Doc.DM298
Rev.2.0