Make sure the extension cord is in good shape. When using an extension cord, verify the gauge is enough for the power that your product
needs. A lower gauge cord will cause voltage drop in the line, resulting in power loss and overheating.
The following table shows the right size to use depending on the cord´s length and the ampere capability shown in the tool's nameplate.
If in doubt, use the next higher gauge. The lower the gauge, the heavier the cord will be.
Make sure that your extension cord is properly grounded and in good shape.
Minimum gauge for extension cords (AWG)
(for 127 V~ only)
Ampere Capacity
(2)
Higher than
Up to
Number of
Conductor
0 A
10 A
10 A
13 A
13 A
15 A
15 A
20 A
(1) It is safe to use only if the extensions themselves have an artifact for over current protection.
(2) One of the conductors should be grounded. All conductors are the same gauge including the one that is grounded.
Reference: NMX-J-195-ANCE
FOR THE BOAC-1-1/2

OVERLOAD PROTECTION

The pump has a thermomagnetic protector that prevents the motor from overheating. The motor shuts off when the switch is turned on,
to reset it, follow these steps:
1. Disconnect the power cord to ensure the pump is off.
2. Allow the pump to cool for at least 5 minutes.
3. Press the thermal switch located on the top cover of the motor.
4. Connect the power cord to turn on the pump.
NOTE: If The unit shuts down again, please go to an Authorized Truper
Extension Gauge
From 5.9' to
Higher than 49.2'
49.2'
3
18 AWG (1)
16 AWG
3
16 AWG
14 AWG
3
14 AWG
12 AWG
3
8 AWG
6 AWG
Service Center.
®