CONNECTIONS
Description
19
24
Accessory power supply 24 V DC
18
-24
17
OPEN
It controls the opening if the gate is stopped.
If the gate is closing, it inverts the movement.
16 PED/C
It controls the pedestrian opening if the gate is closed.
L
It controls the closing if the gate is opened or stopped.
15
SEQ
It controls the opening if the gate is closed.
It controls the closing if the gate is stopped.
14
STOP
It controls the stopping of every movement and, if enabled, it prevents any movement.
13
PH1
Photocell 1 input: during closing, it inverts the movement and, if enabled, it prevents
closing.
M1
12
PH2
Photocell 2 input: it stops any movement. If enabled it prevents any movement. When
disabled: opening.
11
SAF
Input for safety edge.
10
COM
Common inputs
9
+AUX
Remote warning light of automation status:
• flashing fast during closing;
• flashing slow during opening;
• fixed light: swing gates NOT closed;
• light off: swing gates closed
8
+TST
If dip 9 ON: Safety devices Test Out
If dip 9 OFF: LED flashing light Out
7
MCL
Motor Closing Winding
6
MOP
Motor Opening Winding
M2
5
MCOM
Motor Common
4
L
Line 230 V AC
3
N
Neutral 230 V AC
2
PE
Earth 230 V AC
M3
1
PE
Earth 230 V AC
20
GND
Radio Antenna Ground Connection
M4
21
ANT
Radio Antenna Pole
25
CLL
Closed gate limit switch
24
OPL
Open gate limit switch
M5
23
-24
Common inputs
22
24
Accessory power supply +24 V DC
CN1 Encoder connector
CN2 Additional module connector for second channel output
K3
Three-pin connector for accessories insertion; UNICO receiving radio board connection (alternative to
the integrated receiving unit) - Access control decoder.
DIP1
DIP2
ON
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
Operating logic sequences
Dip Switch DSW1 Configuration
LOGIC
AUTOMATIC
STEP - STEP
SUPER AUTOMATIC
AUTOMATIC WITH STOP
STEP - STEP WITH STOP
SC 230
NOTES
Use OPEN input (Terminal 17)
Use SEQ input (Terminal 15)
Use SEQ input (Terminal 15)
Use SEQ input (Terminal 15)
Use SEQ input (Terminal 15)
12