Connection Between Edge Distance/Counting Frequency; Part Label - Balluff BML-SB/C/E0-Q-M4-0-KA Serie Manual De Instrucciones

Ocultar thumbs Ver también para BML-SB/C/E0-Q-M4-0-KA Serie:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

BML-S _ B/C/E0-Q _ _ _ -M4 _ _ - _ 0-KA _ _ /KA _ _-S284
Incremental Magnetic Linear Encoder
11
Appendix (continued)
11.2
Connection between edge distance/counting
frequency
Edge distance
Controller
(= impulse width)
detects at least
Min. edge
the max.
separation [µs]
counting
frequency [kHz]
D
0.12
8,333
E
0.29
3,448
F
0.48
2,083
G
1
1,000
H
2
K
4
L
8
M
10
N
16
P
24
R
100
1)
Signal periods = 1/4 × counting frequency
11.3

Part label

U B = XX V DC XXXXXX
3)
BML0211
BML-S2B0-Q53F-M410-D0-KA05
Supply voltage
1)
Serial number
2)
Ordering code
3)
Type
4)
Fig. 11-1: Part label BML-S...
www.balluff.com
Controller has
the min. sampling
rate [kHz]
1)
16,667
6,897
4,167
2,000
500
1,000
250
500
125
250
100
200
63
125
42
83
10
20
1)
2)
!
4)
english
25
Tabla de contenido
loading

Este manual también es adecuado para:

Bml-sb/c/e0-q-m4-0-ka-s284 serie