Settings And Adjustments - Bentel Security AMB10 Manual Del Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

AMB10 - 15 - 20

5.2 Settings and adjustments

Only enable connected beams, proceeding as follows:
a) identify beam to be employed (2, 3, 4) by means of the jumper provided in the TX and RX sensors, bearing in
mind that each beam is actually made up of a two-way (out-going and in-coming) beam cluster (see section 4 for
further details);
b
) set to OFF the "BEAM" dip switches of the beams employed located in the MASTER card, which is identified
by the presence of the buzzer.
12VDC-
powering
terminal strip
Supervision signal
enabling jumper
Beam 2, 3, or
4 selection
Off-board 3.6V power pack
connector
AA
battery
Radio Alignment
Button
NO TMP1 opening protection
jumper
NO TMP2 tear-off
protection jumper
ENGLISH
3.6V 2.7Ah
RADIO module
Reset button
Buzzer
12
ISFSLIMRFWL_05_08.doc
Beam enabling DIP
BEAM dip switch
Alarm mode selection DIP
FUNCTION dip switch
Tabla de contenido
loading

Este manual también es adecuado para:

Amb15Amb20

Tabla de contenido