INSTALLATION NOTES
At all times, the amplifier has to be operated under appropriate conditions. This includes that the
operation location provides sufficient ventilation and the device is not exposed to direct sunlight or
direct radiation or reflection from any heat source. Installing the loudspeaker systems choose a location
that is not affected by extreme and / or constant vibration or other mechanical oscillation. Also make
sure that the speakers are installed at locations that are free from dust and / or moisture.
CAUTION
Do not take the risk of electro-shock or shock hazard. To reduce the risk of electro-shock, all connections
have to be accomplished before it is permissible to connect the amplifier to the main supply, Before connecting
the appliance to the mains supply, once again make certain that all connections are carried out correctly and
that no short-circuits exist. The overall sound reinforcement installation has to be in accordance to the
laws, regulations, standards, and guidelines that are relevant and applicable in the country where the
equipment is going to be operated.
AC POWER SUPPLY CAUTION
Before using the amplifier for the first time, make sure that the appliance's voltage is in accordance to
your mains supply. Connect the amplifier only to grounded mains outlets. Connecting the amplifler to
the mains supply(230Vac) has to be accomplished by inserting the supplied mains cord into the
corresponding socket and afterward plugging it into a mains outlet.
DESCRIPTION
PA 100 is an installed sound amplifier that can operate with low impedance or 70/100V line loudspeakers.
The operating mode is selected through a switch in the rear side and a dipswitch block which has some
terminals reserved for future improvements.
It incorporates an unbalanced LINE input with its own volume control and LEDs which mark the signal
presence and limit state.
In the rear side is allocated a RJ45 connector which admit RS485 commands from an external device in
order to control some features.
TECHNICAL SPECIFICATIONS
Output Power
Audio Inputs
THD +N
Frequency Response
Main Supply AC power
Dimensions
Weight
2x 50W @ 8Ω / 100W (70/100V Line)
1 LINE (unbalanced), 1 RJ45 (RS485 commands)
1 kHz, 15W, 8Ω/16Ω ≥0,1%
1 kHz, 30W, 70V/100V ≥0,2%
20 Hz-20kHz 0dB - 0.5dB
230 V - 50/60Hz
215x48x264mm(WxHxD)
2.3 kg.