Tacho/Frequency Meter - Kübler CODIX 924 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

7.8.4.3 Mainmenu for configuration
Mainmenu for matching the input
pulses and display
Multiplication factor
Multiplication factor can be
programmed from 00.0001 to
99.9999.
The setting 00.0000 will not be
accepted
Division factor
Division factor can be
programmed from 01.0000 to
99.9999.
The setting <01.0000 will not be
accepted
Decimal point setting
Decimal point (only optical
function)
0
0.0
0.00
0.000
0.0000
0.00000
Set value
Set value can be programmed
from -999999 to 999999
A previously programmed
decimal point will be displayed
Display colour (for device 6.92x.x1x3.xx0)
Display colour
upper line
lower line
Display colour
upper line
lower line
7.8.4.4 Mainmenu for reset mode
Setting the reset mode
www.kuebler.com
no decimal place
1 decimal place
2 decimal places
3 decimal places
4 decimal places
5 decimal places
red
red
red
green
Manual reset (with red key) and
electrical reset (reset input)
No reset possible (red key and
reset input inhibited)
Only electrical reset possible
(reset input)
Only manual reset possible (red
key)
7.8.4.5 Preset 1
See below 7.8.6.5
7.8.4.6 Preset 2
See below 7.8.6.8

7.8.5 Tacho/Frequency meter

7.8.5.1 Mainmenu for the Signal and
Control inputs
Mainmenu for programming the
signal and control inputs
Input polarity
PNP: switching to Plus
for all inputs in common
NPN: switching to 0 V
for all inputs in common
Filter for the signal inputs Inp A and Inp B
maximum count frequency
damped to approx. 30 Hz
(for control with mechanical
contacts)
Page 11
Tabla de contenido
loading

Tabla de contenido