Quick Start; Remaining Menus - Uponor T-33 Guía Rápida

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29
6.4

Quick start

The following sections describe briefly how to set up Uponor
Thermostats T-36 and T-38 and Timer I-36. For full descriptions
of the operation, see Uponor Control System Wired, Installation
and Operation Manual.
NOTE!
There are no quick settings required for Uponor
Thermostat T-36 unless you wish to enable the auto-
matic balancing function. See section
6.4.1
CLK – Clock settings (I-36 and T-38)
To set the clock parameters:
1. Press and hold the OK button for 3 seconds.
The screen displays CLK (clock).
2. Press OK to enter the clock menu.
The screen displays YR (year) and four digits designating the
year are blinking.
3. Press the + and - buttons to change the setting.
4. Press OK to confirm the setting.
Successively the screen displays the sub-menus MTH
(month), DAY (day), TME (time), and S/W (summer-winter
time).
5. Adjust the setting of each sub-menu with the + and - buttons
and confirm the setting with the OK button.
The screen displays the next menu PRG (programming). The
default schedule is applied, see figures below:
Workdays schedule:
Weekend schedule:
6. Proceed with one of the following actions:
Press and hold the OK button for 3 seconds.
The screen returns to run mode.
Press OK to continue with the PRG menu.
The programming menu is used to adjust the settings for
comfort and economy modes. See Uponor Control
System Wired, Installation and Operation Manual for
details.
6.4.2
BAL – Balancing mode (T-36 and T-38)
The auto-balance function removes the need for manual
balancing of the manifold at installation. The principle for
automatic balancing is that the energy required by each loop is
distributed in pulses. The length of the pulses in each loop is
calculated from the actual heat demand of the room.
To enable the auto-balancing function:
1. Press and hold the OK button for 3 seconds.
UPONOR CONTROL SYSTEM WIRED - QUICK GUIDE
The screen displays CLK (clock).
2. Press the + or - button to until BAL is displayed.
3. When BAL is displayed, press OK to enter the menu.
The screen displays one of the following:
4. Press the + or - button to select the preferred setting.
5. Press OK to confirm the setting.
6.4.2, page
9.
6. Press and hold the OK button for 3 seconds.
The screen returns to run mode.
6.4.3
The adjustment of the remaining thermostat parameters is
described in Uponor Control System Wired, Installation and
Operation Manual.
MAN – manual balancing
AB – automatic balancing

Remaining menus

9
Tabla de contenido
loading

Este manual también es adecuado para:

T-34T-35T-36T-37T-38I-36

Tabla de contenido