This system has been tested and certified by the Water Quality Association according NSF/ANSI 42 and 53 for the reduction
of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a
concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42 and 53.
The system has also been tested and certified by WQA according to NSF/ANSI 372 and CSA B483.1.
Substance
Chlorine, Taste, & Odor
NSF/ANSI 42
Chloramine
Aesthetic Effects
Particulate Class 1 particles
0.5 to < 1µm
Mercury Reduction pH 8.5
Mercury Reduction pH 6.5
Lead Reduction pH 8.5
NSF/ANSI 53
Health Effects
Lead Reduction pH 6.5
MTBE Reduction
Turbidity
VOC Surrogate Test
Asbestos Reduction
While testing was performed under laboratory conditions, actual performance may vary.

General Operating Information:

UC300 Rated Capacity
UC100 Rated Capacity
Min-Max operating pressure:
Min-Max feed water temperature:
Rated Service Flow
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after
the system.
Refer to the owners manual for specific installation instructions, manufacturer's limited warranty, user responsibility, and
parts and service availability.
For parts and service availability, please contact Brondell.
The estimated replacement time of filter, which is a consumable part, is not an indication of quality guarantee period, but it
means the ideal time of filter replacement. Accordingly, the estimated time of filter replacement may be shortened in case
it is used in an area of poor water quality.
System and installation shall comply with all state and local regulations.
Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
CORAL UC300/UC100 Filtration
System Performance Data Sheet
Average Percent
Reduction
98.0%
98.6%
99.8%
Cyst
99.99%
96.9%
96.9%
99.2%
99.7%
96.9%
96.6%
99.8%
99.96%
600 gallons (2271 L)
300 gallons (1135 L)
35 psi – 100 psi (241 kPa – 689 kPa)
39 º F – 100 º F (4 º C – 38 º C)
0.50 gpm (1.89 lpm)
Models: Coral UC300 & UC100
Maximum Permissible Product
Influent Challenge
Water Concentration or Minimum
Concentration
Allowable % Reduction
(mg/L unless specififed)
(mg/L unless specififed)
2.00 ± 10%
3.00 ± 10%
minimum
10,000 particles/mL
minimum
≥ 99.95% Reduction
50,000 particles/L
0.006 ± 10%
0.006 ± 10%
0.15 ± 10%
0.15 ± 10%
0.015 ± 10%
11 ± 1 NTU
3.00 ± 10%
100-1000 MFL
≥ 50% Reduction
0.5
≥ 85% Reduction
0.002
0.002
0.010
0.010
0.005
0.5 NTU
≥ 95% Reduction
≥ 99% Reduction