Safety Reverse Force Adjustment; Auto-Close Setting; Photo Beam Setting; Start Terminal - Aprimatic GA-MATIC PRO CF800 Instrucciones De Instalación Mecánica, Uso Y Mantenimiento

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

6.3

SAFETY REVERSE FORCE ADJUSTMENT

6.4

AUTO-CLOSE SETTING

6.5

PHOTO BEAM SETTING

6.6

START TERMINAL

Connecting a touch off switch to this terminal, you can use the switch when maintaining or the transmitter is left in
garage.
7

SPECIAL FUNCTION INTRODUCTION AND APPLICATION

1. The START interface available
Add another START button to open or close the door.
2. Flash light function
Connect the flash light with DC 24V, current ≤ 100mA.
3. Pass door protection (optional)
This function ensure that the door can't be opened unless the small pass door is closed. The door panel won't be
damaged. Connect according to Fig.10.
24
Press SET button and hold on until the LED displays 3. It's under
force adjustment mode.
Press UP button to increase the force and DOWN button to
decrease the force. The maximum force is 9 and the minimum is
1.
Press SET button to confirm.
Press UP button and hold on until the LED displays '-'.
Press UP button once, the auto-close time will increase 1 minute,
the maximum time is 9 minutes.
Press DOWN button the auto-close time decrease 1 minute. The
auto-close function will be turned off when LED displays 0. Press
SET button to confirm.
Press DOWN button and hold on until the LED displays 11.
Pressing UP button, the LED displays H, photo beam function is
available.
To cancel this function press DOWN button, the LED displays 11.
When setting is finished, press SET to confirm.
Notice: Close the photo beam function when you don't use photo
beam sensor.