Product Features - Procom Heating MNSD100TBA Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

WARNING: Heater becomes
very hot when running. Keep
children and adults away from hot
surfaces to avoid burns or cloth-
ing ignition. Heater will remain
hot for a time after shutoff. Allow
surfaces to cool before touching.
WARNING: Do not place cloth-
ing or other flammable material
on or near the appliance. Never
place any objects in the heater.
1. Do not place propane supply tank(s) inside
any structure. Propane supply tank(s)
must be placed outdoors.
2. Heaters with a maximum input over
6,000 Btu/Hr shall not be installed in a
bathroom. Heaters with a maximum input
over 10,000 Btu/Hr shall not be installed
in a bedroom.
3. This heater needs fresh air ventilation to
run properly. This heater has an Oxygen
Depletion Sensing (ODS) safety shutoff
system. The ODS shuts down the heater
if not enough fresh air is available. See
Air for Combustion and Ventilation, pages
7 and 8. If heater keeps shutting off, see
Troubleshooting, page 25.
4. Keep all air openings in front and bottom
of heater clear and free of debris. This will
ensure enough air for proper combustion.
SAFETY PILOT
This heater has a pilot with an Oxygen Deple-
tion Sensing (ODS) safety shutoff system. The
ODS/pilot shuts off the heater if there is not
enough fresh air.
2 GAS OPTIONS AVAILABLE
Your heater is equipped to operate on either
Propane or Natural gas. The heater is shipped
from the factory ready for connecting to Pro-
pane. The heater can easily be changed to
4
SAFETY
5. If heater shuts off, do not relight until you
6. Do not run heater:
7. Before using furniture polish, wax, carpet
8. Manual Control Models Only: Always
9. Do not use heater if any part has been
10. Turn off and unplug heater and let cool
11. Operating heater above elevations of
12. To prevent performance problems, do not

PRODUCT FEATURES

Natural gas by having your qualified installer
follow the instructions on page 14 and the
markings on the heater.
These heaters have a control valve with a
thermostat sensing bulb. This results in the
greatest heater comfort and may result in
lower gas bills.
www.usaprocom.com
have provided fresh, outside air. If heater
keeps shutting off, have it serviced.
• Where flammable liquids or vapors are
used or stored.
• Under dusty conditions.
cleaner, or similar products, turn heater off.
If heated, the vapors from these products
may create a white powder residue within
burner box or on adjacent walls or furniture.
run heater with control knob at PILOT/
IGN, LOW (1) or HIGH (5) locked positions.
Never set control knob between locked
positions. Poor combustion and higher
levels of carbon monoxide may result.
under water. Immediately call a qualified
service technician to inspect the room
heater and to replace any part of the
control system and any gas control which
has been under water.
before servicing. Only a qualified service
person should service and repair heater.
4,500 feet could cause pilot outage.
use propane fuel tank of less than 100 lbs.
capacity.
THERMOSTATIC CONTROL
(Thermostat Models Only)
200213-01C

Capítulos

Tabla de contenido

Solución de problemas

loading

Tabla de contenido