Omron E5AR-T Manual De Instrucciones página 8

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 46
Examples of typical settings
E5AR-TQ4B 100 to 240 V AC
Input type:
Pt100
(–200.0 - 850.0˚C)
Control method: PID control
Output:
Pulse voltage output
Control period:
0.5 sec
Alarm 1:
Absolute-value
upper-limit alarm
200.0˚C
1. Turn on power
2. Set input type
3. Set control mode
4. Set alarm type
7
Program :
SP
(˚C)
Segment 2
Segment 3
Program 1
0.0
Time (Hour: Minute)
Turn on power
Operation Level
25 . 0
Present value / set point
0
0
.
01
01
Program No. Segment No.
.
Hold down for at least 3 seconds to make display 3
Control stops
show l.0 (input default setting level).
(For multi-point input types, the control of all channels stops.)
Input Default Setting Level
Input 1 type
i1-t
Input type
2: K(1)-200.0 - 1300.0˚C
2
appears
l. 0
UD
Input Default Setting Level
Input 1 type
Use the UD keys
i1-t
2→0: Pt100(1) -200.0 - 850.0˚C
0
to change the
l.0
input type
Press for less than 1 second to make display 3
show l. 1 (control default setting level)
Control Default Setting Level
Output 1 type
o1-t
Check the
0:Pulse voltage output
0
Output 1 type
l.1
M
Control mode
mode
Check the control
0:Standard PID control
0
mode
l.1
Press for less than 1 second to make display 3
show l.3 (alarm setting level).
Alarm Setting Level
Alarm type 1
alt1
Use the UD keys
2→8: Absolute-value
8
to change the
l.3
alarm type
Hold down for at least 1 second to return to the
operation level.
Segment 4
SSR
Voltage output: 12 V DC
l.0
1. See the input
l.0
* Check the input
l.1
2. See the output
*
:means
press the key
repeatedly until
the desired
setting data
appears.
l.3
3. See the
upper-limit alarm
Control object
COM
Alarm 1
SUB1
SUB2
IN1
OUT1
allocation list
(p. 9)
type switch.
type list (p.9)
alarm type
list (p. 9)
Temperature sensor:
Pt100
Tabla de contenido
loading

Este manual también es adecuado para:

E5er-t

Tabla de contenido