Positioning; Positioning For Fully Built-In Models; Connection To The Electricity Main - Isotherm Clear Ice Manual De Instalación, Uso Y Mantenimiento

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 40

5.2 POSITIONING

It is advisable to install the appliance in a room
where the temperature is between 10°C and
35°C, and with a water supply temperature of
between 3°C and 25°C.
Avoid installing the appliance where it may be
exposed to direct sunlight or near heat sources
such as radiators, stoves, dishwashers, etc.
This appliance
must not be used outdoors
must not the installed in damp places or where
it is liable to be sprayed with water
must be positioned at a distance of at least 5
cm from the side walls (this does not apply to
built-in models).
5.2.a POSITIONING FOR BUILT-IN MODELS
Ventilation is ensured by the grille on the front panel;
it is therefore not necessary to leave any gap, except
to facilitate installation.
A hole must be made in the surface where the
appliance is to be located as shown in Table (A)
(see Fig. 5) so that the power cable, water feed pipe
and the water drainage pipe can be passed through.
The plug and water supply and drainage
connections must be accessible from the front panel.
To access these, disconnect the appliance from the
power supply, unscrew the screws (13) that hold
the front panel in place (14) and after opening the
door (see Fig. 6) pull out the panel from above.
Before fitting the appliance in place, the power cable
must be fixed to the base plate as shown in the
diagram in Fig. 6.
Fit the front panel back in place after making these
connections.
Pass the plug and cable (15) through the hole
(16) in the plate.
Position the cable clamp (17) in its housing.
Width "l"
540 mm
595 mm
705 mm
Table A
18
Depth "p"
Height "a"
430 mm
470 mm
510 mm
502 mm
625 mm
560 mm

5.3 CONNECTION TO THE ELECTRICITY MAIN

Before connecting the appliance to the
electricity main, make sure that the mains
voltage rating corresponds to the value
indicated on the rating plate.
Make sure that the appliance is connected
to an efficient earthing system.
Make sure that the capacity of the power
supply system suits the maximum power value
indicated on the rating plate of the appliance.
To ensure that the appliance is correctly
and safely installed, provide an adequate socket
controlled by an omnipolar circuit-breaker (9 Fig.
4), with a contact opening gap of not less than 3
mm, in accordance with current national safety
standards. This switch must be equipped with
fuses, with the associated residual current
device positioned in such a way as to be readily
accessible.
Fit the plug (8 Fig. 4) into the switch socket (9 Fig.
4).
The plug must only be replaced by professionally
qualified and authorized personnel, and the new
plug must comply with current national safety
standards.
If the appliance comes supplied without a plug and
you wish to connect it permanently to the power
supply, prepare an omnipolar circuit-breaker, with a
contact-opening gap of not less than 3 mm, in
accordance with national safety standards currently
in force. This switch must be equipped with fuses,
with the associated residual current device
positioned in such a way as to be readily accessible.
This operation must be carried out by a specialized
technician.
X
144 mm
181 mm
291 mm
Y
31 mm
35 mm
35 mm
Tabla de contenido
loading

Este manual también es adecuado para:

5s21a14a00000

Tabla de contenido