YOUR IMMERSION DETECTOR IS NOW ACTIVE,
Make sure that you are no longer in TEST mode: the siren must be at full volume (100dB)
You must always perform additional fall tests at different locations in the pool (including steps);
the siren will go off loudly. If you do not stop it manually by moving the magnet over the swimmer
symbol, the siren will sound for 1 minute and 30 seconds.
Check that the alarm can be heard from the residence/living quarters.
4. Using Sun™/Confort™
The magnets must be kept out of the reach of children under five.
• Certain rough weather conditions (strong winds, storms, etc.) and the use of certain powerful
cleaning equipment can cause untimely alarm triggering.
• Your alarm system will not operate if the water in the probe is frozen or the surface of the
pool is frozen. It is hard to know when the water is frozen in the tube. If in doubt, check that
your immersion detector is working properly.
• When cleaning the outside of your device, (waterline, etc.), do not use any high-pressure
cleaning apparatus, abrasive brush and/or other implements which might scratch or damage
your immersion detector.
• To ensure proper operation of your device, please keep the water pure and clean (in particular,
to avoid algae formation inside the probe).
• You are reminded that the French act No. 2003-9 dated 3 January 2003 on swimming pool
safety requires that a device be installed permanently throughout the year.
Your retailer or AstralPool, or MG International cannot be held liable in the event of drowning
after the removal or complete stopping of your alarm system for whatever reason.
• Should you restart your immersion detector after a long period, perform the tests described
in item 3.7. In case of a problem, contact your retailer immediately.
• The only authorized operation on the device once it is installed is changing the battery.
• Regularly check that your fall detector is working properly by performing the monthly tests
mentioned in this guide (see page 8), or have it checked by a professional.
• Some cleaning robots like diving robot are incompatible with immersion detection systems.
• The performance as defined in standard NF P90-307/A1 is not guaranteed beyond wind levels
greater than those specified in this standard.
WITH THE INDICATOR LIGHT OFF.
PRECAUTIONS FOR USE
17