Troubleshooting; Technical Specifications - STEINEL PROFESSIONAL HF 3360 COM1 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
For information on making claims under the terms of the warranty, please go to
www.steinel-professional.de/garantie
If you have a warranty claim or would like to ask any question
regarding your product, you are welcome to call us at any time
on our Service Hotline 01733 366700.

10. Technical specifications

Dimensions
Surface-mounted installation, round Ø
(L × W × H)
Surface-mounted installation, square
Concealed installation, round Ø
Concealed installation, square
Output
Incandescent lamps, max. 2000 W at 230 V AC
Fluorescent lamps, max. 1000 W
at cos j = 0.5, inductive load at 230 V AC
8 x max. 58 W each, C ≤ 176 µF
*
at 230 V AC
Mains power supply
220-240 V, 50 / 60 Hz max. 2.5 mm
Angle of coverage
360° with 180° angle of aperture
Mounting height
2-2.8 m
Application
inside buildings
Sensor system
5.8 GHz high frequency
Transmitter power
approx. 1 mW
Time setting
5 s - 15 min + pulse mode (approx. 2 s)
Twilight setting
2 – 1000 lux + teach mode
Manual override
selectable (4 h)
(permanent light)
IP rating
Surface-mounted: IP54
Temperature range
- 20°C to + 50°C
*
Fluorescent lamps, low-energy lamps, LED lights with electronic ballast
(total capacity of all ballasts connected below the level stated).
126 × 52 mm
95 × 95 × 52 mm
124 × 64 mm
94 × 94 × 64 mm
2
Concealed: IP20
26

11. Troubleshooting

Malfunction
Cause
No power at the sensor
n Fuse faulty, not
switched ON
n Short circuit
n Additional two-way
switch OFF
n Fuse faulty
Sensor will not switch ON
n Bulb faulty
n Twilight setting set to
night-time mode during
daytime operation
n Additional two-way
switch OFF
n Fuse faulty
Sensor will not switch OFF
n Continuous movement
in the detection zone
n Manual override activat-
ed (red LED lights up)
n Another sensor is par-
allel-connected and still
active
Sensor keeps switching
n Curtains, plants etc.
ON/OFF
moving in the sensor's
detection zone causing
the sensor to respond
Sensor responds when it
n Sensor near Wi-Fi or
should not
other wireless commu-
nication sources
LED flashes once every 15 s
n Load connected
is too high
Remedy
n Replace fuse, turn ON
power switch, check
lead with voltage tester
n Check connections
n Switch ON
n Fit new fuse, check
connections if neces-
sary
n Change bulb
n Adjust setting
n Switch ON
n Fit new fuse, check
connection if necessary
n Check zone
n Deactivate manual
override
n Wait for time setting
of the other sensor to
elapse
n Check zone
n install at least 2 m away
from the wireless com-
munication source
n Reduce load or use
contactor
27
Tabla de contenido
loading

Tabla de contenido