Operation
Resistance Measurements
WARNING:
Never test resistance on a live circuit.
1. Set the rotary function switch to
the
CAP position.
2. Press the MODE button until "M "
appears on the LCD display.
3. Insert the black test lead into the negative
COM input jack. Insert the red test lead
into the positive
input jack.
4. Touch the test probe tips across the
circuit or component under test. It is
best to disconnect one side of the
device under test so the rest of the
circuit will not interfere with the
resistance reading.
5. Read the resistance on the LCD display.
Continuity Test
WARNING:
Never test continuity on a live circuit.
1. Set the rotary function switch to
the
CAP position.
2. Press the MODE button until " "
appears on the LCD display.
3. Insert the black test lead into the negative
COM input jack. Insert the red test lead
into the positive
input jack.
4. Touch the test probe tips to the circuit
or wire you wish to check.
5. If the resistance is approximately 30
or less, an audible tone will sound. If
the circuit is above 400 , the LCD
display will indicate "OL". The resistance
will be shown on the display if it is
below 400 .
Ohms
MODE
RANGE
REL
HOLD
Auto
Power
Off
CAT III 600V
10A
COM
!
!
For
30sec.
MAX
every
15 min
FUSED
WIRE
MODE
RANGE
HOLD
REL
Auto
Power
Off
CAT III 600V
10A
COM
!
!
For
30sec.
MAX
every
15 min
FUSED
9
Operation
Diode Test
WARNING:
Never test diodes in a live circuit.
1. Set the rotary function switch to
the
CAP position.
2. Press the MODE button until " "
appears on the LCD display.
3. Insert the black test lead into the negative
COM input jack. Insert the red test lead
into the positive
input jack.
4. Touch the test probes to the diode under
test. Forward voltage will indicate 0.4 to
0.7V. Reverse voltage will indicate "OL".
Shorted devices will indicate near 0mV
and an open device will indicate "OL" in
both polarities.
Capacitance Measurements
WARNING:
Safely discharge capacitors before taking capacitance
measurements.
1. Set the rotary function switch to
the
CAP position.
2. Press the MODE button until "nF"
appears on the LCD display.
3. Insert the black test lead into the negative
COM input jack. Insert the red test lead
into the positive
input jack.
4. Touch the test leads to the capacitor
to be tested.
5. Read the capacitance value on the LCD
display. The meter will automatically
adjust ranges between nF and µF. Large
capacitors may take up to a minute to
get a stable reading.
Red
Black
Black
Probe
Probe
Probe
FORWARD TEST
REVERSE TEST
MODE
RANGE
HOLD
REL
Auto
Power
Off
CAT III 600V
10A
COM
!
!
For
30sec.
MAX
every
15 min
FUSED
10
Red
Probe