Display control

12.6.1. Monitoring

This menu includes a series of screens which show the main variables being monitored. To move between the
different screens use the keys
The structure and interpretation of the variables of this menu are shown below:
Pac
AC power, in watts
Pwatt
Power fed to the public grid in self-consumption mode, in watts.
Ratio
Self-consumption ratio. Displays the consumption percentage of the loads being fed by the power
generated by the inverter.

12.6.2. Events

This menu shows the events occurring in the inverter.
Alarms
The alarms indicate current events in the inverter that lead to its shut-down. In section "17.1. Alarms. LED
messages" you can consult the list of alarms and their solution.
Warnings
The warnings are events that do not lead to the shut-down of the inverter but do need maintenance action. In
section "Warnings" you can consult the list of warnings and their solution.
Reasons for shutdown
Log file that indicates the alarms that have triggered the inverter shutdown, indicating the date and time of the
shutdown.
Reset stop reasons
This option resets the Stop reasons log file.

12.6.3. Start/Stop

The operation of the inverter can be stopped and started manually using this option.

12.6.4. Settings

In this menu you can make the following settings:
Date and time
To modify the date and time of the inverter.
Languages
Selection of the language for the text on the inverter display.
Modbus ID
Assignation of a number that identifies the inverter. In photovoltaic installations with
more than one inverter, each one must be assigned a different number. Ingeteam
recommends using correlative numbering.
Partial deletion
Deletes the partial meters.
Grounding
Not applicable.
Contrast
To adjust the screen contrast of the inverter.
String settings
Not applicable.
Power settings
Reduce the unit power.
Test fans
By accessing this option it is possible to run a test to check the inverter fans are working
properly.
Diesel grid
Intended for hybrid installations whereby the grid is generated by a diesel generator.
From this menu you can select whether or not the inverted is managed using the
INGECON EMS Manager.
Factory reset
This returns the inverter to factory default status.
ABF2013IQM01_ - Installation and Operation Manual