Problems - Causes - Solutions - Volpi V_BLACK E-PRO16 Manual De Uso

Pulverizador a mochila eléctrico
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

At the end of the re-charge it is recommended to disconnect the battery charger from the power network first and then
from the sprayer;
During long periods of inactivity, check that the general switch A (Fig. "A") is off.
The battery life mostly depends on the observance of some important rules:
Do not create a short-circuit.
Do not discharge it excessively: when the battery is almost discharged, charge it immediately.
Promptly recharge it with the general on/off switch turned off and respecting the necessary time of charging.
For the recharge exclusively use the battery charger supplied with the sprayer.
Do not turn the sprayer on when the battery charger is connected.
After the complete recharge keep the battery between 5 and 40° C.
In case of long stocking or non-use, recharge the battery every four months.
When the battery is no longer rechargeable it is necessary to replace it with another one with the same sizes and features,
respecting the connection polarities; the old battery shall be taken to an authorized collecting point.
7.
PROBLEMS – CAUSES – SOLUTIONS
PROBLEMS
When activating the handle
lever, no water is coming out
Little water comes out when
pressing the handle lever
Battery working time is not as
expected
____________________________________________________________________________________________________________________________________________________________________________________________________________
DAVIDE E LUIGI VOLPI S.p.A. - Via San Rocco,10 - 46040 CASALROMANO (MN) - ITALY
Davide e Luigi Volpi S.p.A.
Via San Rocco,10 – 46040 Casalromano (MN) – Italy
Tel. +39 0376.76009 - 76012 Fax. +39 0376.76408
www.volpioriginale.it
E-mail:
Motor does not work
Motor works
Lower working time
No endurance
POSSIBLE CAUSES
General switch off
Pressure regulator off
Exhausted battery
Blocked pump
Broken cable
Engine failure
Blown fuse
Clogged nozzle
Clogged tank filter
Clogged handle filter
Defective pump
Pressure regulator at minimum
Dirty nozzle filter
Dirty handle filter
Defective pump
Dirty nozzle
Battery not fully charged
Defective battery charger
Exhausted battery
Broken cable
Defective battery charger
Exhausted battery
YLB20VBE_0 Libretto d'uso V_BLACK E-PRO 16
SOLUTIONS
Turn on general switch
Switch on the regulator
Replace or recharge
Contact the service centre
Contact the service centre
Contact the service centre
Replace the fuse
Clean
Clean
Clean
Contact the service centre
Raise the regulator
Clean
Clean
Contact the service centre
Clean
Recharge the battery
Replace
Replace
Contact the service centre
Repair or replace
Replace
pag. 17 di 40
Tabla de contenido
loading

Tabla de contenido