S&P Stylvent HV-230 A-E Instrucciones De Montaje página 9

Ocultar thumbs Ver también para Stylvent HV-230 A-E:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
ENGLISH
FllTlNG AND WlRlNG INSTRUCTIONS
lmportant recommendations
Before installing the device or performing any maintenance, make
sure all the safety instructions listed below, will be fully met:
-The installation must be in accordance with the electrical
standards and regulations in force in your country and by qualified
personnel.
- Precautions must be taken to avoid the back-flow of gases into the
room from the open flue or other fuel-burning appliances.
-Ensure the shutter arm is located into the shutter slot when the
External grill is fitted. Finally check for correct running and shutter
operation.
-If the fan operates as an extractor in a room with a boiler or any
other type of appliance requiring air for combustion check that air
replacement inlets are sufficiently sized.
-Ensure that the values of voltage and frequency of main supply are
compatible with those indicated on the rating plate of the
appliance.
-The electrical installation shall include an isolating switch that has
a contact clearance distance of at least 3 mm.
-Please ensure that a suitable isolator switch is provided in the
electrical circuit. The HV-Series fans are of Class II (double Electrical
Insulation), and therefore do not need to be connected to earth.
-The device is designed for use in places where the ambient
temperatures does not exceed +40ºC.
- This appliance can be used by children aged from 8 years and
above and persons with reduced physical, sensory or mental
capabilities or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance in a
safe way and understand the hazards involved. Children shall not
play with the appliance. Cleaning and user maintenance shall not
be made by children without supervision.
.- Children of less than 3 years should be kept away unless
continuously supervised.
.- Children aged from 3 years and less than 8 years shall only switch
on/off the appliance provided that it has been placed or installed in
its intended normal operating position and they have been given
supervision or instruction concerning use of the appliance in a safe
way and understand the hazards involved. Children aged from 3
years and less than 8 years shall not plug in, regulate and clean the
appliance or perform user maintenance.
-The installer shall provide access to the fan to facilitate future
maintenance, and ensure it is properly secured and installed.
-Motor HV-150N models incorporate a thermal fuse, while the
motors fitted to models HV-230N and HV-300N include a thermal
protector with automatic reset.
-Do not use these extractors for potentially explosive or corrosive
environments.
-Check perfect condition and unpacking operation as any
manufacturing defect that is covered by this warranty S&P.
-The HV range is designed to the be installed in either glass
windows and walls.
Mounting on glass Windows or wall thickness between 3 and 25
mm
-Cut a hole following the dimensions indicated on fig. A. It is
recommended that this should be a minimum of 1500mm from
ground level.
-Dismantle the HV-fan in accordance with the following
instructions:
Fig. 1.- Loosen the retaining screw (b) fixing the internal front cover
(a).
Fig. 2.- Remove the internal front cover (a) by pressing the knobs
(c).
Fig. 3.- Unscrew the 3 bolts (d) fixing the external grille (e) and
separate from the support plate (f).
-lnstall the HV-fan as follows:
Fig. 4.- Pull the external grille (e) towards you and turn the rubber
mounting (g) on the screws (h), towards he inner side of the grille.
Fig. 5.- From the outside, place the external grille (e) over the hole
in the glass. From the inside, turn and push the rubber mountings
(g) until they are located against the glass keeping the external
grille (e) in its correct position.
Fig. 6.- Mount the support plate (f) to the screws (h) of the external
grille (e) and tighten the bolts (d) to suit the thickness of the glass:
- Glass thickness 3 - 14 mm: Fig. 6a
- Panel thickness 14 - 25 mm: Fig. 6
Tighten the screws taking care not to flatten the rubber joints
between the support plate and the external grille.
Ensure that the glass is not in contact with the plastic frame.
Fig. 7.- Make the necessary hole in the gland (i), and feed the
electrical cables through the clamp (p) and correct them in the
terminal box (k).
Fig. 8.-Mount the internal cover (a) by slotting the retangular
openings (1) on the top of the cover (a) into the receivers (m) of the
support plate (f) until the two knobs (c) are correctly positioned.
Fig. 9.-Tighten the locking screw (b)
Wall mounting (extended fixing rod set accessory must be used)
-Cut a hole in the wall where the unit is to be mounted, in
accordance with the dimensions indicated in Fig. A. It is
recommended that this should be a minimum of 1500mm from
ground level.
-Measure the thickness of the wall and cut the threaded rods (n) 5
mm shorter than this thickness.
-Use the appliance to mark on the wall the position of the fixing
holes for the support plate (f), drill the fixing holes and insert the
wall plugs.
loading

Este manual también es adecuado para:

Stylvent hv-300 a-e