3. Connect your appliance to gas cock from the shortest way and in a
manner to prevent any leakage. For safety, the hose used should be max-
imum 125 cm and minimum 40 cm.
4. While making gas leakage control; never use lighter, match, glowing
cigarette or similar inlammable matter.
5. Apply soap bubble on connection point. If any leak/leakage exists,
foaming will occur on soaped region.
6. If the cooktop is to be mounted on a cabinet or openable drawer, a
heat protection panel having 15 mm minimum opening should be mount-
ed under the cooktop.

SETTING GAS COOKTOPS AS PER GAS TYPE

Gas type (LPG or natural gas) that your appliance is manufactured for
is stated in the label found behind the product and that show technical
features. If gas setting of your appliance is not the same as gas setting
of your network, it should be adjusted by making change by an expert
person. In the following table, injector, gas low and power values of ap-
pliance is given according to gas type.
Large
Burner
Wok
Burner
Medium
Burner
Small
Burner
Injector
mm
Gas Flow
g/h
Power
kW
Injector
mm
Gas Flow
g/h
Power
kW
Injector
mm
Gas Flow
g/h
Power
kW
Injector
mm
Gas Flow
g/h
Power
kW
GB
LPG (Cylinder)
G30-30 mbar
0.85
198
2.75
0.96
259.20
3.60
0.65
115.20
1.60
0.50
64.80
0.90
10
Natural gas
G20-20 mbar
mm
1.15
g/h
0.263
kW
2.75
mm
1.30
g/h
0.300
kW
3.35
mm
0.97
g/h
0.165
kW
1.70
mm
0.72
g/h
0.086
kW
0.90
Tabla de contenido