GYS GYSFLASH 30-24 HF Manual De Instrucciones página 14

Ocultar thumbs Ver también para GYSFLASH 30-24 HF:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29
CHANGE BATTERY MODE
The GYSFLASH will maintain a stabilised power supply to the vehicle during battery replacement to preserve memory settings.
Voltage selection
It can be set to operate on 6V, 12V or 24V for changing the battery :
BATTERY CHANGE MODE CONFIGURATION
CHANGE BATTERY
12V
CHANGE BATTERY
12V
• Push the START/STOP key to start the mode.
• During use the current consumed and the instanta-
neous voltage are displayed.
• When changing the battery ensure the polarity is
correct. While exchanging the batteries, be careful
not to disconnect the charger clamps to avoid loss of
electronic data.
Warning: polarity reversal can damage the vehicle electronics.
POWER SUPPLY MODE (OPTIONAL)
This mode is intended for expert users only. This mode enables the charger to be used as a stabilised power supply, with regulated
voltage and adjustable maximum current. By default this mode is inactive and doesn't appear in the mode list. It can be activated via
the menu «Advanced Menu» (see page 16).
Adjustment of the voltage regulation and current limitation :
The voltage regulation can be adjusted from 2V to 30V and the maximum current from 2A to 30A (or from 2A to 15A above 16V):
POWER SUPPLY MODE CONFIGURATION
POWER SUPPLY
U=13.5V
POWER SUPPLY
U=19.6V
POWER SUPPLY
U=19.6V
NOTE: Unlike the other modes, when in Power Supply mode, the charger does not compensate for voltage loss. In this mode,
the voltage displayed is the charger output (and not the voltage on the clamps).
14
GYSFLASH 30-24 HF
6V
12V
24V
I<30A
2.0V
2.1V
...
I<15A
30.0V
2A
2A
3A
3A
...
I<10A
30A
15A
Start up :
• Connect
1 : Black clamp to the vehicle chassis or earth.
2 : Red clamp to the (+) of the battery / battery terminal,
in such a way that the battery can be changed without
disconnecting the clamp.
STARTING BATTERY CHANGE
CHANGE BATTERY
U=12V
Start up with battery:
• Push the START/STOP key to start the mode.
• During use the current consumed and the instanta-
neous voltage are displayed.
STARTING POWER SUPPLY
POWER SUPPLY
...
U=19.6V
CHANGE BATTERY
U=12.9V
POWER SUPPLY
I<15A
U=19.6V
EN
I=26A
I=10A
Tabla de contenido
loading

Tabla de contenido