TROUBLESHOOTING
Indication
Investigation
cause
False
continuous
auX connector
activation:
discharge from the
not fully inserted
soap
nozzle
dispensing
Random discharge
Reflection issue
from the nozzle
from other
object
soap discharging
damaged pump
from pump
due to high
housing.
viscosity or
debris in pipes
soap not
Pump is making
soap tank is
dispensing
sounds when
empty
sensor is activated
soap dispenser
has not been
primed
damaged pump
(discharge from
housing)
debris or dried
soap in the pipe
or tank
High viscosity
soap
(> 3800 cPs)
Bent pipes
12
solution
Illustration
the connector should be inserted fully
until white o-ring is not visible. Remove the
O-RING VISIBLE –
NOT CONNECTED PROPERLY
o-ring if necessary
ONLY THE GROOVES ARE VISIBLE –
CONNECTED PROPERLY
eliminate any cause of reflection and if
necessary use appropriate remote control to
shorten detection range.
min 1.5 m
Replace the Pump. Rinse warm water
through the pipe and the body of the soap
dispenser all the way to the nozzle.
Fill with soap with correct viscosity (100
- 3800 cPs) and prime pipes using the fill
button on remote control.
Prime the soap dispenser by pressing the
fill button on the remote or by pressing the
refill button located at the bottom of the
Press
pump, until soap exits the nozzle.
FILL
Button
Replace the Pump
Run warm water through pipe, pump, and
body all the way to the nozzle. Replace with
soap of correct viscosity.
note: using the soap dispenser with
high viscosity soap may cause permanent
damage to the pump and shorten the
lifecycle.
unbend or straighten pipes.
TROUBLESHOOTING
Indication
Investigation
soap not
Pump is
dispensing
not making
sound
when the
sensor is
activated
soap Viscosity
(100 - 3800 cPs)
cause
solution
sensor is
auX connector not
the connector should be inserted
blinking
fully inserted
fully until the white o-ring is
when hand
not visible. Remove the o-ring if
is placed in
necessary
front
Refill button on
Replace the Pump. Rinse warm
pump does not
water through the pipe and the
activate the pump.
body of the soap dispenser all the
way to the nozzle.
damaged pump
(discharge from
housing).
debris or dried soap
Run warm water through pipe,
in the tank or tubing
pump, and body all the way to the
nozzle. Replace with soap of correct
viscosity.
note: using the soap dispenser
with high viscosity soap may cause
permanent damage to the pump
and shorten the lifecycle.
sensor is
Refill button on
transformer: check operation with
not blinking
pump does not
functioning transformer. Where
when hand
activate the pump.
necessary replace with appropriate
is placed in
transformer. For part numbers see
front
spare parts list.
Battery: check operation with
functioning battery pack. Where
necessary, replace batteries or
replace the battery pack: Battery
pack (without batteries)
Reflection issue
eliminate any cause of reflection
from other object
and use appropriate remote control
to shorten detection range.
damaged sensor
If the above two solutions have
not resolved this issue replace
with appropriate sensor. For part
numbers see spare parts list.
Illustration
O-RING VISIBLE –
NOT CONNECTED PROPERLY
ONLY THE GROOVES ARE VISIBLE –
CONNECTED PROPERLY
Press
Refill
button
min 1.5 m
Replace
sensor
13