Repair Parts; Specifications; Warranty - Pentek INTELLIDRIVE PID-1-4A7-1-01 Manual De Instalación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Repair Parts / Warranty

REPAIR PARTS

Part Description
Input Terminal Block Connector
Output Terminal Block Connector
Cooling Fan
Pressure Transducer
10' Transducer Cable
25' Transducer Cable*
50' Transducer Cable*
100' Transducer Cable*
150' Transducer Cable*
200' Transducer Cable*
Cord Grip for Transducer Cable*
Keypad
* Purchase Separately
PENTAIR WATER warrants to the original consumer purchaser ("Purchaser" or "You") of the products listed
below, that they will be free from defects in material and workmanship for the Warranty Period shown below.
Product
Water Systems Products –
jet pumps, small centrifugal pumps,
submersible pumps and
related accessories
PENTEK INTELLIDRIVE
Pro-Source™ Composite Tanks
Pro-Source™ Steel Pressure Tanks
Pro-Source™ Epoxy-Line Tanks
Sump/Sewage/Effluent Products
Our warranty will not apply to any product that, in our sole judgement, has been subject to negligence,
misapplication, improper installation, or improper maintenance. Without limiting the foregoing, operating a
three phase motor with single phase power through a phase converter will void the warranty. Note also that
three phase motors must be protected by three-leg, ambient compensated, extra-quick trip overload relays of
the recommended size or the warranty is void.
Your only remedy, and PENTAIR WATER's only duty, is that PENTAIR WATER repair or replace defective
products (at PENTAIR WATER's choice). You must pay all labor and shipping charges associated with this
warranty and must request warranty service through the installing dealer as soon as a problem is discovered.
No request for service will be accepted if received after the Warranty Period has expired. This warranty is not
transferable.
PENTAIR WATER SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT
DAMAGES WHATSOEVER.
THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND
IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING WARRANTIES
SHALL NOT EXTEND BEYOND THE DURATION EXPRESSLY PROVIDED HEREIN.
Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on
the duration of an implied warranty, so the above limitations or exclusions may not apply to You. This warranty
gives You specific legal rights and You may also have other rights which vary from state to state.
This warranty supersedes and replaces all previous warranty publications.
Warning: In a domestic environment, this product may cause radio interference, in which case supplementary mitigation
measures may be required.
Qty.
Part No.
1
PID-CON2
1
PID-CON3
1
PID-FAN-R
1
U17-1561-R
1
U18-1593
1
U18-1594
1
U18-1595
1
U18-1596
1
U18-1597
1
U18-1598
1
U17-1337
1
PID-HMI-R
LIMITED WARRANTY
PENTAIR WATER, 293 Wright St., Delavan, WI 53115

SPECIFICATIONS

Drive:
Max Input Amps: . . . . . . . . . . . . . . . . . . . . . . . . . . .17A
Max Output Amps . . . . . . . . . . . . . .See Table 1, Page 4
Input/Output Terminal Capacity . . . . . . . . . . .6-14AWG
Input Frequency . . . . . . . . . . . . . . . . . . . . . . . .50/60Hz
Input Voltage . . . . . . .230VAC Nominal (190–265VAC)
Output Voltage: PID-1 . . . . . . . .230VAC/30-80Hz/3 Ph
Output Connections . . . . . . . .3-Phase, 3-Wire/1-Phase,
Max Motor Cable Length . . . . . . . . . . . . . . . .1,000 Ft.*
Ambient Temperature . . .–4°F to 104°F(–20°C to 40°C)
Transducer:
Pressure Range: . . .0-100 Pounds per Square Inch (PSI)
Output Signal: . . . . . . . . . . . . . . . . . . . . . . . . .4-20mA
Pressure Port: . . . . . . . . . . . . . . . . . . . . . . . . .1/4" NPT
Rated Voltage . . . . . . . . . . . . . . . . . . . . . . . .8–28VDC
* Limit with no external filter
Warranty Period
whichever occurs first:
12 months from date of original installation, or
18 months from date of manufacture
12 months from date of original installation, or
18 months from date of manufacture
5 years from date of original installation
5 years from date of original installation
3 years from date of original installation
12 months from date of original installation, or
18 months from date of manufacture
PID-6 . . . . . . . .230VAC/30-60Hz/1 Ph
or 2-Wire/1-Phase
16
Tabla de contenido
loading

Tabla de contenido