Sauna Heater Safety Clearances - Helo HIMALAYA Pure Manual De Uso

Ocultar thumbs Ver también para HIMALAYA Pure:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 78
Installation and User Manual Himalaya Pure
2.9.

Sauna heater safety clearances

Out-
Sauna room
put
Volume
min.
max.
kW
6.8
5
9
10.5
9
15
Table 1 Safety clearances
Corner and wall installations: The OLET 31 sensor is installed 40 mm from the ceiling on the centre line of the heater on a
wall. Alternatively, the sensor can be installed on the ceiling above the centre of the heater – see 'middle installation' for instruc-
tions. The heater must be secured to the floor or the sauna bench structure in order to keep the safety distances the same.
OLET 31
A
Wall support
Heater mounting
point to wall or
sauna bench
Middle installation: If the sauna heater is installed further than 60 mm off a wall or a corner, the installation method is always
middle installation. The heater must be attached to the benches or to a similar structure using a wall support. The OLET 31
sensor is always installed on the ceiling.
A
Figure 2 Safety clearances
Heater minimum clearances
Height
From side to
wall
A
min. mm
mm
1900
60
1900
60
mm
330
D
H
mm
F
870
A
H
1900
Wall support
Heater mounting
point to wall or sauna
bench
To ceiling
From front to sauna
bench
D
mm
mm
60
870
60
870
OLET 31
A
mm
Wall support
Heater mounting
point to wall or
sauna bench
OLET 31 sensor
position in a ceiling
installation above the
heater within the
330 mm diameter.
Amount of stones
In kg, approx.
100
100
Absolute measure,
when the sensor
OLET 31 installed on
the wall.
Water tank
330
7
Tabla de contenido
loading

Este manual también es adecuado para:

1104-70-0405111104-105-040511

Tabla de contenido