7.0 POSSIBILIBIES OF FAILURE
1 Compressor does not run at starting pressure:
* blown fuse
* tank at pressure
* motor broken
* defective pressure switch
2 Repeating thermal failure:
* blown fuse
* loose wire
* pressure switch does not releave
air circuit
* too low voltage
* overloading
3 Compressor keeps blowing off air:
* defective non-return valve
4 Too little air production:
* dirty air filter
* defective valves
* draintap condensation water is open
5 Leaking safety valve:
* pressure too high
* defective safety valve

8.0 TECHNICAL DETAILS

Type
Order number
Number of cylinders/stages
Motorpower
Volt
Air tank
Oil tank
Operating pressure
Maximum pressure
Sound pressure level
Air intake capacity
Protected with
Service
Weight
Dimensions (lxwxh)
Modelchanges reserved.
All compressors are provided with Euro-Norm (CE-Choice)
All manuals and user guides at all-guides.com
- renew the fuse
- discharge
- repair/renew
- repair/renew
- renew fuse
- repair
- repair/renew valve
- remove extension cable or use heavier
- reduce loading
- repair/renew
- clean/renew filter
- renew
- close the draintap
- set pressure switch
- renew
HL 360/50 compact
36852
1/1
2,5 Hp/1,8 kW
230 V/50 Hz
50 litres
0,8 litres
6 bar
8 bar
78 dB(A)/7 m
360 l/min.
16 amp.
30% per 60 minutes
38 kg
480x410x1050 mm