I Replacing The Brushes - Zodiac RV 5480 iQ Manual De Instalación Y De Uso

Robot eléctrico
Ocultar thumbs Ver también para RV 5480 iQ:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 99

5.3 I Replacing the brushes

• Each brush is equipped with wear indicators; the distance between the indicators and the end of the brush indicates
whether the brush is in good conditi on (see image
• The brushes are worn and should be replaced when the wear indicators appear as shown in image
• To remove worn brushes, remove the tabs from the holes in which they are fi xed (see image
• To fi t new brushes, start by fi tti ng the side without tabs under the brush holder (see image
• Roll the brush around its support, slide the tabs into the att achment holes and pull on the end of each tab unti l its
edge passes through the slit (see image
• Cut the tabs using a pair of scissors for them to be level with the other blades (see image
).
).
.
).
).
).
EN
19
Tabla de contenido
loading

Tabla de contenido