6
Safety Notes
6 Gloves should be worn during installation to prevent
crushing and cutting injuries.
6 The shower system may only be used for bathing,
hygienic and body cleansing purposes.
6 The hot and cold supplies must be of equal
pressures.
Installation Instructions
• The fitting must be installed, flushed and tested after
the valid norms.
• Prior to installation, inspect the product for transport
damages.
After it has been installed, no transport or surface
damage will be honoured.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Hansgrohe mixers can be used together with
hydraulically and thermically controlled continuous flow
heaters if the flow pressure is at least 0,15 MPa.
The product is exclusively designed for drinking water!
Fault
Mixer stiff
Mixer dripping
Hot water temperature too low, no
cold water. Instantaneous water
heater starts up when cold water is
selected.
4
English
Symbol description
max. 1 MPa
0,1 – 0,5 MPa
1,6 MPa
max. 80°C
65°C
Cause
- Cartridge defective, calcified
- Cartridge defective, sedimentation
- Hot water limiter incorrectly set
- Crossflow
Assembly see page 32
Do not use silicone containing acetic acid!
Adjustment
To adjust the hot water limiter on single lever
mixers, please see page 36. No adjustment
is necessary when using a continuous flow
water heater.
Dimensions (see page 33)
Flow diagram
(see page 33)
Operation (see page 37)
Cleaning
Cleaning recommendations, see enclosed
brochure.
Spare parts (see page 38)
XXX = Colors
000 = chrome plated
090 = chrome plated/gold plated
800 = stainless steel optic
Test certificate (see page 35)
Remedy
- Exchange cartridge
- Exchange cartridge
- Set hot water limiter
- Exchange cartridge