3
Installation
3.6.1 Rear view (connection
holes)
Place the burner plates, burner plate caps and
grills back to their seating after installation.
3.7 Gas conversion
WARNING: Before starting any
A
work on the gas installa-tion, dis-
connect the gas supply.
There is the risk of explosion!
In order to change your appliance's gas type,
change all injectors and make flame adjustment
for all valves at reduced flow rate position.
Exchange of injector for the burners
1. Take off burner cap and burner body.
2. Unscrew injectors by turning the counter-
clockwise.
3. Fit new injectors.
4. Check all connections for secure fitting and
tightness.
New injectors have their position
C
marked on their packing or injector
table on Injector table, page 12 can
be referred to.
18 / EN
(Varies depending on the product
model.)
C
On some hob burners, the injector
is covered with a metal piece. This
metal cover must be removed for in-
jector replacement.
1. Flame failure device (model dependant)
2. Spark plug
3. Injector
4. Burner
Unless there is an abnormal condi-
tion, do not attempt to remove the
C
gas burner taps. You must call an
Authorised service agent or techni-
cian with licence if it is necessary to
change the taps.
3.7.1 Reduced gas flow rate
setting for hob taps
1. Ignite the burner that is to be adjusted and turn
the knob to the reduced position.
2. Remove the knob from the gas tap.
3. Use an appropriately sized screwdriver to adjust
the flow rate adjustment screw.
For LPG (Butane - Propane) turn the screw clock-
wise. For the natural gas, you should turn the
screw coun-ter-clockwiseonce.
» The normal length of a straight flame in the re-
duced position should be 6-7 mm.
4. If the flame is higher than the desired position,
turn the screw clockwise. If it is smaller turn an-
ticlockwise.
Built-In Hob / User Manual