USE INSTRUCTIONS
ATTENTION!
BEFORE INSERTING THE KEY INTO THE CYLINDER PLACE YOUR HAND ON
THE WALL IN ORDER TO ELIMINATE ANY ELECTROSTATIC
CHARGE ACCUMULATED.
KEY WARNING LIGHTS
Battery charge status warnings without introducing User or Programming key into cylinder.
To see battery charge status keep centre of key grip pressed on warning light side for around 3 seconds:
• 1 green flash: battery charged
• 1 yellow flash: battery almost flat
• 1 red flash: battery flat
User key warnings whilst introducing key into cylinder:
• 1 green flash: key enabled to open; battery charged
• 1 yellow flash: key enabled to open; battery almost flat
• 1 red flash: key enabled to open; battery flat
• 2 red flashes: key not enabled to open
Programming key warnings whilst introducing key into cylinder:
• 1 green flash: key has already carried out operation on cylinder; battery charged
• 1 yellow flash: key has already carried out operation on cylinder;
battery almost flat
• 1 red flash: key has already carried out operation on cylinder; battery flat
• 2 red flashes: key not enabled to carry out operations on cylinder
• Short green flashes: data loading or unloading operation. This operation stops with a visual
warning that lasts twice as long as previous flashes and is coloured:
o Green, if data transmission is correct and battery charged;
o Yellow, if data transmission is correct and battery almost flat;
o Red, if data transmission is correct and battery is flat;
o Double red flash, if error has been noted during data transmission
REPLACING BATTERIES IN KEY
ATTENTION!
BATTERIES MUST NOT BE REPLACED IN POTENTIALLY EXPLOSIVE
ATMOSPHERE ROOMS
Use only LITHIUM SONY CR1620 3 Volt (70mAh) batteries.
Open cap turning in
anti-clockwise direction
Remove cap and lift gold tab slightly.
Turn key to let batteries out
CSF
Insert new batteries, positioning
them one at a time under the
gold tab. Close cap turning in a
clockwise direction until locked
19