Programming The Dips-Switch - FAAC E012S Manual De Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
Tab. 1 - Operation of inputs status LEDs
LED
ON (closed contact)
STOP
Command disabled
OPEN A
Command enabled
OPEN B
Command enabled
BUS

6.2. PROGRAMMING THE DIPS-SWITCH

The following tables show the settings of the DS1 dip-
switch for programming force, pre-flashing and reversing
stroke.
Tab. 2 - DS1 programming (default settings in bold)
DS1
DS2
DS3
DS4
OFF
OFF
OFF
ON
ON
OFF
ON
ON
ON
OFF
ON
OFF
If you connect an electric lock to terminal J4,
position DS4 to ON to enable the reversing stroke
(before opening, the motors thrust to close, thus
facilitating the electric lock to uncouple).
By setting dip-switch DS3 on ON, a special
antiwind function is activated that enables the
gate operation even if strong wind is present.
6.3. PRE-FLASHING
The pre-flashing function can be activated and disabled
(following an OPEN command, the unit activates the
flashing lamp for 3 seconds before it starts the move-
ment). Procedure:
1.
Press LOGIC key (SW3) for at least 5 secs. to aCTIVATE
pre-flashing.
2.
Press SPEED key (SW2) for at least 5 secs. to dESACTI-
VATE pre-flashing.
In both cases check if the LED of the pressed key
changes its status: in such cases it means that
the function of the key and not the pre-flashing
was changed.
6.4. TIME - SETUP LEARNING
Before any manoeuvre is executed, a SETUP
cycle must first be run.
During SETUP do not interrupt the photocells
because their interruption causes the immediate
stop of the leaves. To end the procedure, repeat
SETUP from the beginning.
When the board is powered up and a SETUP cycle has
never been executed, LEDs LD4 and LD5 begin to flash
slowly to signal that a SETUP cycle must be executed.
There are two possible types of SETUP: AUTOMATIC and
MANUAL.
OFF (open contact)
Command enabled
Command disabled
Command disabled
See par. 7.2
Description
LOW FORCE
MEDIUM - LOW FORCE
MEDIUM - HIGH FORCE
HIGH FORCE
ANTI-WIND ON
ANTI-WIND OFF
REVERSING STROKE ON
REVERSING STROKE OFF
6.4.1. AUTOMATIC SET-UP
To execute an AUTOMATIC SETUP , follow the procedure
below:
Take the leaves to mid-point.
1.
2.
Hold down the SETUP (SW1) push-button until the
2 adjacent LEDs (LD4 and LD5) light up on steady
beam.
3.
Release the SETUP push-button, LEDs LD4 and LD5
begin to flash rapidly.
4.
Leaf 2 (if present) starts the closing movement, stop-
ping when it reaches the closing mechanical stop.
5.
Leaf 1 starts the closing movement, stopping when it
reaches the closing mechanical stop.
6.
Leaf 1 starts the opening movement.
7.
Leaf 2 (if present) starts the opening movement after
a fixed delay at opening.
Leaves 1 and 2 (if present) stop when they reach the
8.
opening mechanical stop.
9.
Wait for LEDs LD4 and LD5 to go OFF, which means
that the SETUP procedure has finished.
10.
Give an OPEN pulse to close the gate.
When the SETUP procedure has been started,
if the leaves at point 4 and 5 open instead of
closing, the motor power supply cables must be
changed over.
When using the AUTOMATIC SETUP , the slow down
spaces, the leaf opening and closing delays,
and the pause time (30 sec., with A logic), are all
preset by the board and cannot be modified.
6.4.2. MANUAL SET-UP
To execute a MANUAL SETUP, follow the procedure
below:
1.
Take the leaves to mid-point.
2.
Hold down the SETUP (SW1) push-button until the
leaves start to move.
3.
Release the SETUP push-button, LEDs LD4 and LD5
begin to flash rapidly.
4.
Leaf 2 (if present) starts the closing movement, stop-
ping when it reaches the closing mechanical stop.
Leaf 1 starts the closing movement, stopping when it
5.
reaches the closing mechanical stop.
6.
Leaf 1 starts the opening movement.
7.
Leaf 2 (if present) starts the opening movement after
a fixed delay at opening.
8.
Leaves 1 and 2 (if present) stop when they reach the
opening mechanical stop.
9.
If LOW force was set, wait for about 5 sec checking
if the flashing lamp goes OFF.
10.
At this point:
If logic A was selected, the board starts to count the
pause time (max. 10 minutes). At the end of the
required time, send an OPEN impulse to continue
the procedure, leaf 2 (if present) starts the closing
movement and the board starts to count the leaf
delay at closure.
If logic EP was selected, the board starts the closing
movement immediately, without waiting to receive
any impulses, and, if leaf 2 is present, the board
starts to count the leaf delay at closure.
11.
At the end of the required delay, send an OPEN im-
pulse to the leaf 1 to start the closing movement. If
leaf 2 is not present, one-leaf installations, the OPEN
impulse sent according to point 10 directly causes
the closure of leaf 1.
12.
Leaves 1 and 2 (if present) stop when they reach the
closing mechanical stop.
13.
Wait for LEDs LD4 and LD5 to go OFF, which means
that the SETUP procedure has finished.
When the SETUP procedure has been started,
if the leaves at point 4 and 5 open instead of
12

Capítulos

Tabla de contenido
loading

Tabla de contenido