FUNCTION .................................. DEFAULT
parameters
LO
Logic ...........................................AUTOMATIC
PA
Pause time.....................................
Electric lock .............................................DISABLED
.
ELS
IF CONNECTED ENABLED AUTOMATICALLY
.
LAm
Pre-fl ashing time ...............................
.
tA
Additional time at end of movement ..
.
t1
Additional time after reverse .............
nM
Number of wings ............... automatically detected
Direction wing 1 .....................................
. ;
.
d1
d2
Direction wing 2 .....................................
.
Mod
Operator type ................................ HYDRAULIC
Power wing 1 .......................................MAX
.
E1
Power wing 2 .......................................MAX
.
E2
(
-
ONLY ELECTRO
MECHANICAL OPERATORS
.
rEL
Electronic slowing............................ ENABLED
.
PSET
Restore factory settings (default)
.
man
Access MAINTENANCE menu
RadI
Access MEMORIES menu
Prof
Access ADVANCED programming
A1
Wing 1 closing delay ...........................
A2
Wing 2 opening delay .........................
A3
Pedestrian opening ..........................DISABLED
A4
Electric lock actuation time ...................
A5
Electric lock advance .........................
Reverse stroke time .........................DISABLED
A6
IF ELECTRIC LOCK CONNECTED
A7
Maximum torque time following startup ..
A8
Reverse time at end of closing ...........
A9
Approach speed ...................................
rat
Factory setting - Do NOT modify
LUM
Display luminosity .............................. MEDIUM
Closing when photocell
Ad
uncovered .............................. reloads pause time
Ae
Auxiliary output ........................... WARNING LIGHT
AH
Flashing light during pause ...................OFF
100% fi nal thrust time.....................DISABLED
AM
If electric lock connected ...................
.
Ar
Aux. opening safety device .......with PHOTOCELL
.
tf
Closing photocell test .....................DISABLED
.
An
Aux. opening safety device test ....DISABLED
AL.t
Movement Total counter (cannot be modifi ed)
.
AL
P
Movement Partial counter for maintenance
.
AL
S
Sets maintenance cycle on
.
aL
r
Zero-sets the counter
Saving the remote controls on the
Open
built-in receiver Apricode ...........open the memory
.
rn
Deleting a remote control with address
.
r
tr
Deleting all remote controls
UPLd
Saving control unit data on Plug-in memory module
dnLd
Saving data from Plug-in memory module on control unit
ch1
Remote control Output channel setting
ch1
ch2
................................................. START
ch2
ch3
..................................... PEDESTRIAN START
ch3;ch4
ch4
......................................... DISABLED
SWING APRICODE 230
25
sec.
-
FOLLOWING SELF
TEACH PROCEDURE
3
sec.
6
sec.
6
sec.
0
0
)
5
SDgr
2
SDgr
.
3
5
sec.
.
0
5
sec.
.
0
5
.....................
sec.
1
sec.
0
sec.
30
%
1
sec.
AL.P
AL.P
SETTINGS
0 =
;
4 =
AUTOMATIC
STEP
5 =
;
2 =
MANNED
SUPER AUTOMATIC
3 =
SEMI AUTOMATIC WITH STOP
0 ÷ 60 (1
)
SECOND STEPS
0 =
DISABLED
1 =
ENABLED
1 ÷ 9 (1-
)
SECOND STEPS
3 ÷ 20 (1-
) -
SECOND STEPS
ELECTRONIC SLOWING IS USED
3 ÷ 20 (1-
)
SECOND STEPS
0 =
AUTOMATICALLY DETECTED
0 ; 1
E1
E2
0 =
(
-
HYDRAULIC
NOT
THRUST FORCE ELECTRONIC ADJUSTMENT
0 (
) ÷ 50 (
)
MINIMUM
MAX
0 (
) ; 1 (
)
DISABLED
ENABLED
RED TO CONFIRM
o
RED T
CONFIRM
o
RED T
CONFIRM
o
RED T
CONFIRM
0 ÷ 15 (1
= 5°
STEP
OF DISPLACEMENT
0 ÷ 5 (1
= 2,5°
STEP
OF DISPLACEMENT
0= 20%; 1= 40%; 2= 60%; 3=80%; 4= 100%
3 ÷ 6 (0.5-
)
SECOND STEPS
0 ÷ 1 (0.5-
)
SECOND STEPS
0 ÷ 2 (0.5-
)
SECOND STEPS
Reverse stroke: opening preceded by brief operation in the
reverse direction to facilitate release of the electric lock.
0 ÷ 3 (0.5-
) (only electro-mechanical)
SECOND STEPS
0=0; 1=30; 2=50; 3=80; 4=100; 5=120; 6=150; 7=200; 8=300; 9=400 (
At the end of closing the motors are operated in reverse direction for the
time set to discharge the mechanisms when movement is complete.
1= 30% ; 2= 40% (%
OF MOVEMENT SPEED
0 ÷ 2 -
DO NOT MODIFY
0 ÷ 9
00=
; 01=
IMMEDIATELY
AT THE END OF PAUSE TIME
; 02=
10
. ; 03=
AFTER
SEC
AFTER A NEW COMPLETE PAUSE TIME
)
THE PAUSE TIME
0 =
; 1÷60 =
WARNING LIGHT
START OR PEDESTRIAN START
0=
;
1=
(
OFF
ON
IN AUTOMATIC MODE
0 ÷ 5 (
DURING CLOSING FOR ELECTRIC LOCK ENGAGE
0=
;
1=
SAFETY EDGE
0 =
; 1 =
DISABLED
STANDARD PHOTOCELL TEST
0 =
; 1 =
DISABLED
STANDARD PHOTOCELL OR EDGE TEST
2 =
REFLEX PHOTOCELL OR EDGE TEST
0000 ÷ 9999 (
INCREASES BY
0000 ÷ 9999 (1 = 10
MOVEMENTS
0000 ÷ 9999 (1 = 10
MOVEMENTS
-
-
EACH SETTING ZERO
SETS THE COUNTER
RED TO CONFIRM
(
RED TO CONFIRM
THE DISPLAY SHOWS
0 ÷ 99 (see Programming remote controls)
RED TO CONFIRM
- (
RED TO CONFIRM
OPTIONAL PLUG
- (
RED TO CONFIRM
OPTIONAL PLUG
0 =
;
1 =
DISABLED
START
4 =
AUXILIARY OUTPUT USING EXTERNAL RELAIS
Ae
1÷60
timer 1÷60 if
=
)
- 25 -
CONTROL UNIT
-
-
;
1 =
BY
STEP
FOUR STEPS
;
6 =
(
TIMER
START INPUT
;
ADDITIONAL THRUST IS AT REDUCED SPEED IF
rEl
(
)
; 1 =
; 2 =
SINGLE WING
DOUBLE WING
);
1 =
-
ELECTRO
MECHANICAL
:
)
)
)
(
COUNTING CONTINUES
MINUTES COURTESY LIGHT
NOTE: only if not set on remote control
)
)
PHOTOCELL
; 2 =
REFLEX PHOTOCELL TEST
;
1
100
FOR EVERY
MOVEMENTS
AL.S
) (
RESET USING
OR
)
100
WITH MINIMUM STEP
AL.P
seed
15
.)
FOR
SEC
-
)
IN MEMORY MODULE
-
)
IN MEMORY MODULE
;
2 =
; 3 =
PEDESTRIAN START
(2 sec. pulse if
;
)
.)
MSEC
)
(
RELOADS
ON
AFTER
)
AL.r
)
MOVEMENTS
;
STOP
Ae
0
=
;