Grounding; Connecting To A Building's Electrical - Firman W03381 Manual Para El Propietario

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

adjusting the engine. At high altitudes increased
exhaust emissions can also result due to the increased
enrichment of the air fuel ratio. Other high altitude
issues can include hard starting, increased fuel
consumption and spark plug fouling. To alleviate
high altitude issues other than the natural power
loss, FIRMAN can provide a high altitude carburetor
main jet. The alternative main jet and installation
instructions can be obtained by contacting Customer
Support. Installation instructions are also available
in the Technical Bulletin area of the FIRMAN internet
site.
The part number and recommended minimum
altitude for the application of the high altitude
carburetor main jet is listed in the table below.
Altitude main jet 1
Altitude main jet 2
WARNING

Grounding

The National Electric Code requires your generator
must be properly connected to an appropriate
ground to help prevent electric shock.
WARNING
Failure to properly ground the
generator can result in electric
shock.
A ground terminal connected to the frame of
the generator has been provided on the control
panel. For remote grounding, connect of a
length of heavy gauge (12 AWG minimum)
copper wire between the generator ground
terminal and a copper rod driven into the
English
Altitude
193cc
333717002
3000-6000Feet
333717003
6000-8000Feet
OPEN
ground. We strongly recommend that you
consult with a qualified electrician to ensure
compliance with local electrical codes.
THERE IS A PERMANENT CONDUCTOR BETWEEN
THE GENERATOR (STATOR WINDING) AND THE
FRAME.
Connecting to a Building's Electrical System
Connections for standby power to a building's
electrical system must be made by a qualified
electrician. The connection must isolate the
generator power from utility power or other
alternative power sources and must comply
with all applicable laws and electrical codes.
WARNING
Generator voltage could cause
electrical shock or burn resulting
in death or serious injury.
Use approved transfer equipment to prevent
backfeed by isolating generator from electric
utility workers.
When using generator for backup power, notify
utility company.
Use a ground fault circuit interrupter (GFCI) in
any damp or highly conductive area, such as
metal decking or steel work.
• •
DO NOT touch bare wires or receptacles.
DO NOT use generator with electrical cords
which are worn,frayed, bare or otherwise
damaged.
DO NOT operate generator in the rain or wet
weather.
DO NOT handle generator or electrical cords
while standing in water, while barefoot, or
while hands or feet are wet.
DO NOT allow unqualified persons or children
to operate or service generator.
Page 13
Customer Service: 1-844-FIRMAN1
Tabla de contenido

Solución de problemas

loading

Tabla de contenido