Automatic repositioning
If the programmer blocks due to an encoder count error
programmer reset
, the warning lights and indicator light will flash simul-
taneously for 2 seconds and will then switch off for 10 seconds.
After the programmer has been in this condition for 3 minutes it will (after
pre-flashing for 10 seconds) automatically move the gate, slowly, to the
completely closed position (2 times as in the programming procedure) in
order to recover the correct position.

DISPLAY MODE

Using the PROG button you can access the following functions in
sequence:
- memorising the status of the dip-switches;
- display the status of the command and safety devices;
The status of the security devices
CSP
are always shown on the display.
Memorising
the
DIP-SWITCH
displaying the firmware version (e.g. "V10")
The segments regarding the command status
(LED "ON"
command active) and safety status
The number of manoeuvres appears on the
display. This number always remains visible until
you change the setting. Once 999999 has been
exceeded the lighting up of the decimal point on
the display equals 1 million + the six figure
number.
In the test mode (only activated when the motor
has stopped) it is possible to check the status of
the command and safety devices and carry out
eventual controls. The warning lights will activate
once,
each
time
a
FTCI-CSP" command is received. In this mode
you can activate serial line communication by
using the external program, which is to be
connected to the CSER connection via cable (fig.
3). While communication is active dashes will
appear on the display; after 5 seconds of inactivity
you will be moved back to the
return to the normal operating mode press the
"test" command again and wait for 10 seconds.
Limited opening setting from 1 to 9 metres (in the
example it has been set to 3 metres).
Each time PROG is pressed
the limited opening distance,
measured
in
metres,
increase (from 1 to 9).
10 seconds after the last
modification you will be
automatically moved out of
the mode and the selected
values will be saved (eg. 4)
or after a
TB
FTCi
,
and
PRESS PROG
settings
and
est) light up.
PRESS PROG
PRESS PROG
"TA-TC-TAL-TD-TB-
mode. To
PRESS PROG
10 sec
PRESS
will
10 sec
PROG
At this point the programmer will function normally.
To carry out automatic repositioning without waiting for 3 minutes you may
send a (TA, TC, TAL or TD) command to the programmer.
No commands will be accepted during repositioning but the security devices
will cut in and block all movement if they go into alarm.
PROG
- display the number of manoeuvres;
test
- set the limited opening distance;
- setting the current sensor level
10 sec
10 sec
5 sec
Connect the
programming device
(CSER) and activate it.
PRESS PROG
Setting the current sensor.
10 sec
PRESS PROG
Each time PROG is pressed
the number will increase (from 1
to 3).
10 seconds after the last
modification you will be automatically
moved out of the mode and the
selected values will be saved (eg. 2)
19
.
When the
TA-TC-TD-TAL-TB-FTCI-FTCS
inputs are activated the warning lights will light up.
PRESS PROG
10 sec
que ( max. 9 amps )
PRESS PROG
3 minutes,
10 sec