Lamp Replacement; Lamp Replace Counter - Sanyo PLC-SE10 Manual Del Propietário

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

When the life of Projection Lamp of this projector draws to an end, LAMP REPLACEMENT indicator lights yellow. When a
projected image becomes dark or the color of an image becomes unnatural, replacement of Projection Lamp is required.
CAUTION
For continued safety, replace with a lamp
assembly of the same type.
Allow a projector to cool for at least 45
minutes before you open Lamp Cover. The
inside of a projector can become very hot.
Follow these steps to replace the lamp assembly.
1
Turn off the projector and disconnect AC plug. Allow the
projector to cool at least for 45 minutes.
2
Remove a screw with a screwdriver to remove Lamp Cover.
3
Remove 3 screws with a screwdriver and pull out Lamp
Assembly by grasping Handle.
4
Replace Lamp Assembly with a new one and tighten 3 screws
back. Make sure that Lamp Assembly is set properly. Replace
Lamp Cover and tighten a screw.
5
Connect AC Power Cord to the projector and turn it on.
6
Reset Lamp Replace Counter (refer to the section "Lamp
Replace Counter" below).
NOTE : Do not reset Lamp Replace Counter when Projection
Lamp is not replaced.
ORDER REPLACEMENT LAMP
Replacement Lamp can be ordered through your dealer. When ordering Projection Lamp, give the following
information to the dealer.
G Model No. of your projector
G Replacement Lamp Type No. : POA-LMP50
Be sure to reset Lamp Replace Counter when Lamp Assembly is replaced. When Lamp Replace Counter is reset, LAMP
REPLACE Indicator stops lighting.
1
Turn projector on, press MENU button and ON-SCREEN MENU will appear. Press POINT LEFT/RIGHT button(s) to
move a red frame pointer to SETTING Menu icon (refer to page 35, 36).
2
Press POINT DOWN button to move a red frame pointer to "Lamp counter reset" and then press SELECT button. The
message "Lamp replace counter reset?" is displayed. Move the pointer to [Yes] and then press SELECT button.
3
Another confirmation dialog box appears and select [Yes] to reset Lamp Replace Counter.
Do not reset Lamp Replace Counter except after Projection Lamp is replaced.

LAMP REPLACEMENT

: PLC-SE10
(Service Parts No. 610 301 0144)

LAMP REPLACE COUNTER

CAUTION
Do not drop a lamp assembly or touch a glass
bulb! The glass can shatter and may cause
injury.
LAMP COVER
LAMP
ASSEMBLY
APPENDIX
HANDLE
39
Tabla de contenido
loading

Tabla de contenido