JIMTEN T-604 CC Manual De Instrucciones Y Mantenimiento página 24

Triturador sanitario
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

T-604 CC WASTE DISPOSER
5.1. INSTALLING RECOMMENDATIONS.
PIPE – For the discharge use a Ø32 mm pipe. Do not thump of make siphons
with the pipe that may retain certain objects and cause obstructions.
PIPE – For the discharge use a Ø32 mm pipe. Do not thump of make siphons
with the pipe that may retain certain objects and cause obstructions.
Other pipe diameters might be used (Ø28-22 mm) with the joint adap-
ter and metal clamping supplied.
PIPE SUPPORT – Evacuation pipes must be fixed with the appropriate acces-
sories according to the manufacturer indications.
KNEES – Do not use use knees instead. If knees are not available, two 45º
elbows can be employed to make a 90º knee.
AVOID DIAGONAL STRETCHES – Evacuation pipes must be always installed
vertically or horizontally, but never diagonally.
PROTECTION AGAINST FROST – In areas where frost risk due to low tempe-
ratures is high, every stretch in risk of freezing must be protected by
means of thermal insulators.
CONNECTION TO THE FLUSH – The connection to the flush must be carried
out by means of a inclined branch. If the connection to the flush is at a
lower level regarding the waste disposer base, a A-69 Jimten-type
venting valve must be set at the highest point in the installation to
prevent the waste disposer from being emptied.
DISCHARGE – The discharge stretch must be always connected to the evacua-
tion system. Do not evacuate in an open waste pipe, drain, etc.
VENTILATION – The waste disposer unit must be placed right behind the lava-
tory, it should never be installed in wall-embedded installations, behind
walls, etc, which avoid the correct ventilation of motor, which incorpora-
tes a self ventilating mechanism.
SANITARY APPLIANCES – The CICLON CC waste disposer is prepared to
connect a single lavatory and three sanitary appliances (washbasin,
bidet or shower), it does not allow connecting other electric powered
appliances such as washing machines or dish washing machines,
equipped with pumping devices which may interfere the correct working
of the unit.
5.2. CONNECTION TO THE POWER SUPPLY.
The electrical connection must be carried out after having connected all the sanitary appliances and
the evacuation system.
If the waste disposer is installed in a bathroom, it must be linearly separated from the bathtub or
shower at least one metre.
An exclusive 240 V power point is necessary to connect the waste disposer.
It is recommended the installation of a European base 10-16A socket with two poles and earth wire to
it is accessible from the front register and which does not interfere with the casset removal.
The waste disposer must be always connected to a differential protected supply system.
Before starting any maintenance operation, the unit must be disconnected from the power supply.
24 - INSTRUCTIONS AND MAINTENANCE GUIDE