TECO TK 500 Manual De Instrucciones página 13

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
TANK
5.2.1
Information on the display
On:
On:
Flashing light:
Flashing light:
5.2.2
Thermostat settings
Refer to fi gure 15 for buttons detection.
1) To change the temperature of the water:
a. Push the button SET for 3 seconds (Rif. A8), display shows the current value setting, and the unit of
measure icon (C or F ref C3) starts to blinking.
b. Modify the parameters using the arrows
c. Push the button SET (Rif. A8) to confi rm the values.
2) To adjust other parameters: hysteresis function (Hy), probe calibration (Ot), except for the heater (O1):
d. Access to the programming menu by pressing the SET+
icon unit selected starts blinking (C or F ref C3) and appears Hy.
e. Scroll through the parameters using the arrows
eter.
f.
Press the SET button (ref A8), the current set value is displayed.
g. Change the value using the arrows
h. Press the SET button (Ref. A8) to confi rm the setting and move to the next parameter.
i.
Press SET +
NOTE: If you do not press any buttons for 30 seconds, all settings are saved and the device is
ready for operation.
Parameter
Preset value
Hy
Ot
o1
5.3
TRANSPORTATION AND STORAGE
The conditioner must be handled carefully in a vertical position using the handles. It is recommended to placed
it on a fl at surface.
5.4
DEMOLITION AND DISPOSAL
The crossed-out wheelie bin label that can be found on your products, indicates that the product may
not be treated as household waste. By ensuring that this product is disposed of correctly, you will
help preventing potential negative consequences for the environment and human health, which
could otherwise be caused by inappropriate waste handling of these products. For more detailed
information about recycling of this product, please contact your local city offi ce, your household
waste disposal or the dealer where you purchased this product.
This information only applies to customers in the European Union, according to Directive 2002/96/EC of EU-
ROPEAN PARLIAMENT and THE COUNCIL OF 27January 2003 on waste electrical and electronic equipment
(WEEE) and legislation transposing and implementing it info the various notional legal systems. For other coun-
tries, please contact your local government to investigate the possibility of recycling your product.
C H I L L E R L I N E
unit in cooling mode (Ref. A9 Fig. 15).
unit in heating mode (Rif. B1 Fig. 15).
unit ready for cooling (Rif. A9 Fig. 15).
unit ready for heating (Rif. B1 Fig. 15).
(Ref. A8 and C2) to exit programming mode.
1°C
This parameter sets the hysteresis, that is the
0°C
This parameter adjusts the calibration of the
probe: it allows to compensate for the difference
in temperature reading on the display with re-
spect to the actual water temperature.
On
Activating / deactivating the heating resistor: Set
on "On" to activate the heater, set to "OFF" to
and
(Rif. C2 and A7) (5 ÷ 35°C / 41 ÷ 95°F).
button for 3 seconds (Ref. A7 and A8). The
and
and
(Rif. C2 and A7).
Description
differential of the unit.
turn off the heater.
Tab. 5-2
(Ref.C2 and A7) until the desired param-
Regulation range
EN
0,5 ÷ 10°C
1 ÷ 45°F
-9.9 ÷ 9.9°C
-17 ÷ 17°F
On - OFF
11
Tabla de contenido
loading

Este manual también es adecuado para:

Tk 1000Tk 2000

Tabla de contenido