Operation; Function Of Displays; Function Of Buttons; Temp Mode - SKF TIH 030m Instrucciones De Uso

Ocultar thumbs Ver también para TIH 030m:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 40

5. Operation

5.1 Function of displays

The remote control display shows the selected
time or temperature for heating.
The power LED's show the selected power
setting.
Display
Indication
t
time in minutes
°C
temperature in degrees Celcius
°F
temperature in degrees Fahrenheit

5.2 Function of buttons

Button
Function
POWER
Press to adjust the power
The selected power is indicated with an LED
MODE
Press to switch between TIME MODE and TEMP MODE
UP (+)
Press to increase the value shown on the remote control display
DOWN (-)
Press to decrease the value shown on the remote control display
START / STOP
Press to start or stop the heater
The LED on the START / STOP button is lit when the heater is heating
and lashes during temperature measurement

5.3 Temp mode

If the remote control display shows 't' , press MODE to select TEMP MODE.
The remote control display shows °C or °F in TEMP MODE.
The selected temperature is shown on the remote control display.
The default temperature for bearings is 110 °C (230 °F). If a different temperature
is desired, press UP or DOWN to adjust the temperature in steps of 1°.
It may be desirable to heat bearings to temperatures above 110 °C (230 °F) for
increased mounting time. Consult the SKF bearing speciications to determine the
maximum permitted temperature. Always ensure the bearing does not lock due to an
excessive expansion of the inner ring compared to outer ring. See section 5.8.
If needed press POWER to select the power level. Use the guidelines in section 5.8 to
determine the correct power setting.
Make sure the temperature probe is mounted on the bearing inner ring.
Press START / STOP to start the heater. The remote control display shows the current
temperature of the workpiece.
SKF TIH 030m
9
Tabla de contenido
loading

Tabla de contenido