5. MOUNTING ASSEMBLY OF SYSTEM.
- Place the CICLON CS waste disposer in a suitable place and connect every inlet and outlet (see
connection figure on page 11). Provide a one meter minimum distance from the flush to the waste
disposer, so that it can operate during the appropriate time to eliminate the wastes effectively.
- When installed in concealed installations, a registry should be made so maintenance operation
and/or caset removal, is possible. Free area of 30 cm over the caset should be allowed.
- Connect the lavatory evacuation coupling
(normally wall-hung, or horizontal outlet) to the
Ciclon CC.
- Connect the outlet set formed by non-return
valve, PVCb pipe and elbow to the sanitary
macerator outlet threading the 1" nut.
- Check water tightness of both couplings.
- The CICLON CS waste disposer has 2 side
auxiliary inlets provided with non return valve,
and one top auxiliary inlet, by means of a 1
1/2", to connect a single sanitary appliance in
each. If any inlet is not used, there is a plug to
leave it out of action. The unit receives water
from the sanitary appliance by the action of
gravity. The lavatory horizontal stretch to the
waste disposer must have a positive slope (1-
2º slope) and a maximum 0.5 m distance, to
allow drainage when the waste disposer is not
working.
- When a shower base is connected to the waste
disposer, it is essential to provide a minimum
height of 180 mm between the lower part of the
shower base and the waste disposer base,
thus providing the necessary slope towards the
waste inlets. It is recommended to use a non-
syphonic waste pipe when installing the shower
base and the bathtub; otherwise, see figure on
page 25 to install a secondary ventilation
system.
- The CICLON FIT waste disposer has a 32 mm
pipe PVC glue socket, which is equipped with a
non-return clappet valve. In case of obstruc-
tion, for an easy cleaning of the non-return
valve it is recommended to install a shut-off
valve within the vertical discharge pipe that
interrupts its emptying.
- Connect the waste pipe or flush as the waste disposer pumps by means of a 32 mm pipe, up to a
maximum height of 6 m or to a maximum horizontal distance of 62 m, or a combination of both (see
diagram). A constant 1% minimum slope must be considered up to the discharge point.
18 - INSTRUCTIONS AND MAINTENANCE GUIDE
T-604 CS WASTE DISPOSER