14. Troubleshooting guide

PROBLEME
WARNING: Make sure the icing prevention system is not working.
1) Starting failure
2) Lack of power/Poor acceleration/
Rough idling
3) Oil does not come out
If the unit seems to need further service, please consult with an authorized service shop in your area.
GB | Operating Instructions
CAUSE
Check fuel for water or substandard
mixture.
Check for engine flooding
Check spark ignition
Check fuel for water or substandard
mixture
Check air filter and fuel filter for
clogging
Check carburetor for inadequate
adjustment
Check oil for substandard quality
Check oil passage and ports for
clogging
17
REMEDY
Replace with proper fuel
Remove and dry the spark plug.
Then pull the starter again with no
choke
Replace with a new plug
Replace with proper fuel
Clean
Readjust speed needles
Replace
Clean